Texas Instruments TI CC3000 Скачать руководство пользователя страница 22

IMPORTANT NOTICE

Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.

TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.

TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.

TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.

Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.

Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.

Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.

In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.

No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.

Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.

TI has specifically designated certain components which meet ISO/TS16949 requirements, mainly for automotive use. Components which
have not been so designated are neither designed nor intended for automotive use; and TI will not be responsible for any failure of such
components to meet such requirements.

Products

Applications

Audio

www.ti.com/audio

Automotive and Transportation

www.ti.com/automotive

Amplifiers

amplifier.ti.com

Communications and Telecom

www.ti.com/communications

Data Converters

dataconverter.ti.com

Computers and Peripherals

www.ti.com/computers

DLP® Products

www.dlp.com

Consumer Electronics

www.ti.com/consumer-apps

DSP

dsp.ti.com

Energy and Lighting

www.ti.com/energy

Clocks and Timers

www.ti.com/clocks

Industrial

www.ti.com/industrial

Interface

interface.ti.com

Medical

www.ti.com/medical

Logic

logic.ti.com

Security

www.ti.com/security

Power Mgmt

power.ti.com

Space, Avionics and Defense

www.ti.com/space-avionics-defense

Microcontrollers

microcontroller.ti.com

Video and Imaging

www.ti.com/video

RFID

www.ti-rfid.com

OMAP Applications Processors

www.ti.com/omap

TI E2E Community

e2e.ti.com

Wireless Connectivity

www.ti.com/wirelessconnectivity

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265

Copyright © 2012, Texas Instruments Incorporated

Содержание TI CC3000

Страница 1: ...TI CC3000 Evaluation Module User s Guide Literature Number SWRU326 November 2012...

Страница 2: ...w 6 2 2 EM Board Bottom View 9 2 3 Antenna 10 2 4 Hardware Setup 13 2 5 Schematics 14 2 6 Bill of Materials BOM 15 3 Layout Guidelines 16 4 Application Development 21 2 Contents SWRU326 November 2012...

Страница 3: ...5 Antenna and RF Trace Routing Layout Guidelines 19 3 6 Power Supply Routing of the CC3000 EM Board 20 4 1 MSP EXP430FR5739 Test Platform and CC3000 EM Board 21 List of Tables 2 1 Key Parts of CC3000...

Страница 4: ...r s guide and data sheets go to http www ti com product cc3000 FCC Warning This equipment is intended for use in a laboratory test environment only It generates uses and can radiate radio frequency en...

Страница 5: ...are requirements making it ideal for low power and low cost applications The CC3000 EM board is targeted for TI MCUs such as the MSP430 FR5739 and other various host platforms This document details th...

Страница 6: ...rts and jumpers mounted on the top of the CC3000 EM board Table 2 1 describes the key parts of the EM board Table 2 2 describes the J2 configuration of the CC3000 EM board Table 2 3 and Table 2 4 desc...

Страница 7: ...t This tool uses the RS232 UART pins to run radio frequency RF RX and TX tests on the CC3000 module For more information see the CC3000 wiki Functional mode Normal mode Connect pins 2 and 3 Normal mod...

Страница 8: ...from EEPROM inside the CC3000 module This pin is connected to the SDA_CC3000 device using a 0 resistor and is not used by end users 5 VBAT_SW_EN Input Active high enables the signal from the host dev...

Страница 9: ...AT_SW_EN Input Active high enable signal from the host device 12 WL_SPI_IRQ Output Host interface SPI interrupt request 14 WL_SPI_CS Input Host interface SPI CS 16 WL_SPI_CLK Input Host interface SPI...

Страница 10: ...rd and the RF trace routing from the CC3000 module to the antenna Figure 2 4 shows the matching circuit between the antenna and the EM board The return loss is based on the matching circuit and RF tra...

Страница 11: ...Antenna Figure 2 4 Matching Circuit Between the Antenna and the CC3000 EM Board Figure 2 5 Return Loss from the ACX Antenna and Matching Circuit 11 SWRU326 November 2012 CC3000 EM Board Submit Docume...

Страница 12: ...n Avg gain 0 3 2 6 XZ plane Peak gain Avg gain 1 3 4 2 YZ plane Peak gain Avg gain 0 9 0 9 Antenna www ti com Figure 2 6 Antenna Radiation Patterns 12 CC3000 EM Board SWRU326 November 2012 Submit Docu...

Страница 13: ...w headers J4 and J5 To use the EM mating connectors to connect the hardware the mating EM connector must be lined up and spaced 1 2 inches apart see Figure 2 7 To use the single row headers the requir...

Страница 14: ...2 5 Schematics Figure 2 8 shows the schematics of the CC3000 EM board Figure 2 8 Schematics of the CC3000 EM Board 14 CC3000 EM Board SWRU326 November 2012 Submit Documentation Feedback Copyright 201...

Страница 15: ...B 3 J1 Mini RF header receptacle 4 J2 CON male 1 x 3 pitch 2 0 mm 5 J3 CON male 1 x 2 pitch 2 0 mm 6 J6 J7 Female header Fool Proof H 4 3 2 x 10 pitch 1 27 mm SMT 7 C1 C3 CAP 0402 10 pF 50 V NPO 5 8 C...

Страница 16: ...ng a board design incorporating the TI CC3000 module Figure 3 1 shows the TI CC3000 EM four layer board Table 3 1 and Figure 3 2 describe instances of good layout practices Figure 3 1 Module Layout Gu...

Страница 17: ...the inner layers if possible 6 Signal traces can be run on a third layer under the solid ground layer which is below the module mounting layer 1 See Figure 3 2 Figure 3 2 Module Layout Guidelines Fig...

Страница 18: ...ith Layer 2 Table 3 2 Trace Design Measurement Values Measurement Length H height between L1 and L2 12 0 mil W RF trace 14 3 mil T thickness 1 2 mil S separation 10 0 mil r dielectric 4 3 18 Layout Gu...

Страница 19: ...ission line 5 For best results the RF trace ground layer must be the ground layer immediately below the RF trace The ground layer must be solid 6 There must be no traces or ground under the antenna se...

Страница 20: ...ust be at least 18 mil wide Make VBAT traces as wide as possible to ensure reduced inductance and trace resistance If possible shield VBAT traces with ground above below and beside the traces Figure 3...

Страница 21: ..._Wi Fi_for_MCU TI_Platforms In addition to the TI MCU platforms the CC3000 EM board can be used on other platforms with the same RF connector interface For a host driver porting guide to assist with p...

Страница 22: ...egulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related information or support that may be provided...

Страница 23: ...ould void the user s authority to operate the equipment This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may n...

Отзывы: