Setup
5
Setup
1. Download TDC1000-TDC7200 Software (same software for TDC1000_GASEVM)
2. Install the GUI. For detailed information, see
.
3. Connect TDC1000-BSTEVM to TDC1000-GASEVM
4. Connect a gas pipe transducers to the TDC1000-BSTEVM
5. Connect the EVM board to the computer with a USB cable (J2).
6. Launch the GUI. See
7. On the GUI's “SETUP” tab, select the "TDC1000-HV Boost Power Enable", “TDC1000-HV Driver EN1”
and/or “TDC1000-HV Driver EN2” depending on which TX port your transducer is connected to.
8. On the “GRAPH” tab, press the “START GRAPH” button.
9. Select an "EN period (us)" in that matches your excitation duration in
μ
s. For instance if you are using
a 200Khz transducer with 10 excitation pulses the duration = (# pulses/Xmit freq)*1e6+30us or 80 us.
10. Run the GUI as explained in
Figure 1. TDC1000-GASEVM
6
TDC1000-GASEVM and TDC1000-BSTEVM Kit User’s Guide
SNIU026A – March 2015 – Revised December 2015
Copyright © 2015, Texas Instruments Incorporated