Using the GUI Software
11
SLOU481A – August 2017 – Revised October 2017
Copyright © 2017, Texas Instruments Incorporated
TAS5755MEVM Evaluation Module
To initiate the GUI control, the first step is to ‘Connect’ the GUI. To do this, scroll to the
Target
section of
the menu and click on
Connect
(as shown in
Figure 12. Initiating Connect from the Target Menu
After the
Target-Connect
operation, the GUI window background changes from white (with grid) to a solid
light-green. All the blocks seen in the GUI window are now active and any updates made on these blocks
updates the corresponding register space. Also, note that the configuration menu options on the right-
hand side (highlighted with blue-box in
) are now grayed out and cannot be updated. The
Target-
Connect
operation automatically updates the trim register (0x1B) to factory-trim mode, now the device can
be set to stream audio output with only two additional operations: exit-shutdown and un-mute
The device shut-down mode can be toggled through the
Shutdown
checkbox (highlighted with a red-box in
). Uncheck this box to bring the device out of shutdown. Similarly, the mute state of master
volume can be toggled using the
Mute
checkbox (highlighted with a red-box in
). After un-muting
the master volume, use the volume slider to set the volume to the desired level. The current volume level
is displayed in the menu area on the right-hand side of the GUI window. After completing these basic
operations, the device can now stream audio.
Figure 13. Toggling Shut-Down and Mute States