Using the EVM Software
3
Using the EVM Software
3.1
Connect the GUI to the EVM
Once the properties window selections have been made, go to the menu Target
→
Connect.
This sends the initialization commands to the device. Master volume is in mute. Select the master volume
function. Type the required volume in the properties window. For TAS5707/09, type 0 dB. The difference
is due the power stage gain in both devices. At this time, audio, if connected properly, plays through the
device. Check All channel shutdown button. It must be un-checked. When the Connect command is
issued, if an error appears indicating a USB problem, check the connections, and press the USB RESET
button on the controller board. Then disconnect and re-connect from the Target menu.
3.2
I2C Memory Tool
This tool can be opened from GDE (Tools
→
I2C Memory Tool) or independent of GDE from Start
→
Program
→
Texas Instruments Inc
→
Memory Tool.
Select I2C as show in
Figure 12. Memory Tool Window
I2C registers can be written or read using this tool. The I2C command file can be sent by selecting the
command file and
Execute
command.
3.3
Volume Function
The Individual and Master volume can be selected, and the required volume value can be entered by
typing on the property Window after selecting the function with the mouse (see
).
11
SLOU231C – December 2008 – Revised October 2014
TAS5707EVM (TAS5709EVM) User's Guide
Copyright © 2008–2014, Texas Instruments Incorporated