www.ti.com
bq27500
bq27501
System-Side Impedance Track™ Fuel Gauge
SLUS785 – SEPTEMBER 2007
Table 4-7. Data Flash Summary (continued)
Subclass
Data
Min
Max
Default
Class
Subclass
Offset
Name
Units
ID
Type
Value
Value
Value
Configuration
64
Registers
0
Operation Configuration
H2
0x0000
0xffff
0x0979
–
Configuration
64
Registers
2
Pack 0 Voltage
(1)
U2
0
4200
1000
mV
Configuration
64
Registers
4
Pack 1 Voltage
(1)
U2
0
4200
4000
mV
Configuration
64
Registers
8
Pack V% Range
(1)
U1
0
100
5
%
Configuration
68
Power
0
Flash Update OK Voltage
I2
0
4200
2800
mV
Configuration
68
Power
7
Sleep Current
I2
0
100
10
mA
Configuration
68
Power
16
Bat Low Threshold
I2
0
700
100
mAh
Configuration
68
Power
18
Hibernate Voltage Threshold
U2
2400
3000
2550
mV
Gas Gauging
80
IT Cfg
0
Load Select
U1
0
255
1
–
Gas Gauging
80
IT Cfg
1
Load Mode
U1
0
255
0
–
Gas Gauging
80
IT Cfg
48
Terminate Voltage
I2
–32768
32767
3000
mV
Gas Gauging
80
IT Cfg
53
User Rate-mA
I2
0
9000
0
mA
Gas Gauging
80
IT Cfg
55
User Rate-mW
I2
0
14000
0
10mW
Gas Gauging
80
IT Cfg
57
Reserve Cap-mAh
I2
0
9000
0
mAh
Gas Gauging
80
IT Cfg
59
Reserve Cap-mWh
I2
0
14000
0
10mWh
Current
Gas Gauging
81
0
Dsg Current Threshold
I2
0
2000
75
mA
Thresholds
Current
Gas Gauging
81
2
Chg Current Threshold
I2
0
2000
75
mA
Thresholds
Current
Gas Gauging
81
4
Quit Current
I2
0
1000
50
mA
Thresholds
Current
Gas Gauging
81
6
Dsg Relax Time
U2
0
8191
1800
s
Thresholds
Current
Gas Gauging
81
8
Chg Relax Time
U1
0
255
60
s
Thresholds
Current
Gas Gauging
81
9
Quit Relax Time
U1
0
63
1
s
Thresholds
Gas Gauging
82
State
0
IT Enable
H1
0x00
0xff
0x00
–
Gas Gauging
82
State
1
Application Status
H1
0x00
0xff
0x00
–
Gas Gauging
82
State
2
Qmax 0
I2
0
32767
1500
mAh
Gas Gauging
82
State
4
Cycle Count 0
U2
0
65535
0
–
Gas Gauging
82
State
6
Update Status 0
H1
0x00
0x03
0x00
–
Gas Gauging
82
State
7
Qmax 1
I2
0
32767
1500
mAh
Gas Gauging
82
State
9
Cycle Count 1
U2
0
65535
0
–
Gas Gauging
82
State
11
Update Status 1
H1
0x00
0x03
0x00
–
Gas Gauging
82
State
16
Avg I Last Run
I2
–32768
32767
300
mA
Gas Gauging
82
State
18
Avg P Last Run
I2
–32768
32767
1200
mAh
OCVTables
83
OCVa0 Table
0-45
OCVTables
84
OCVa1Table
0-45
See Note
(2)
OCVTables
85
OCVb0 Table
0-64
OCVTables
86
OCVb1 Table
0-64
Default Ra Tables
87
Def0 Ra
0-18
See Note
(2)
Default Ra Tables
88
Def1 Ra
0-18
Rb Tables
89
Rb0 Table
0-18
See Note
(2)
Rb Tables
90
Rb1 Table
0-18
(1)
bq27501 only.
(2)
Encoded battery profile information created by bqEASY software.
Submit Documentation Feedback