6 Configurations
All Jumper selections must be made prior to applying power to the EVM. Configure this EVM using the following
configuration selections.
6.1 Switching Frequency Selection
Switching frequency can be changed as shown in
.
Table 6-1. Switching Frequency Selection
SWITCHING
(ƒ
SW
) (kHz)
RESISTOR DIVIDER RATIO
(R
DR
)
EXAMPLE RF FREQUENCY
COMBINATIONS
R
RF_H
(kΩ)
R
RF_L
(kΩ)
1000
> 0.557
1
300
850
0.461
180
154
750
0.375
200
120
600
0.297
249
105
500
0.229
240
71.5
400
0.16
249
47.5
300
0.096
255
27
200
< 0.041
270
11.5
(1)
Default Setting: 1 MHz.
For different switching frequency setting, please change R3 and R4 as shown in
6.2 Mode Selection
The MODE can be set by J5.
Table 6-2. Mode Selection
JUMPER SET TO:
MODE SELECTION
1 to 2 pin shorted
FCCM with 2x RC time constant
3 to 4 pin shorted
FCCM
5 to 6 pin shorted
with 2x RC time constant
7 to 8 pin shorted
Auto-skip mode with 2× RC time constant
9 to 10 pin shorted
Auto-skip mode with 1× RC time constant
(1)
Default setting.
(2)
The device enters FCCM after PGOOD goes high.
Configurations
SLUUBC0A – DECEMBER 2015 – REVISED AUGUST 2021
TPS548A20 SWIFT™ Step-Down Converter Evaluation Module User's Guide
9