![Texas Instruments SimpleLink Ethernet MSP432E401Y Скачать руководство пользователя страница 1083](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_10955781083.webp)
MII Management (EPHY) Registers
1083
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Ethernet Controller
15.7.28 EPHYRCR Register (Address = 0x1F) [reset = 0x0]
Ethernet PHY Reset Control - MR31 (EPHYRCR)
This register allows the system to reset or restart the PHY by register access.
EPHYRCR is shown in
and described in
.
Return to
Figure 15-116. EPHYRCR Register
15
14
13
12
11
10
9
8
SWRST
SWRESTART
RESERVED
R/W-0x0
R/W-0x0
R-0x0
7
6
5
4
3
2
1
0
RESERVED
R-0x0
Table 15-128. EPHYRCR Register Field Descriptions
Bit
Field
Type
Reset
Description
15
SWRST
R/W
0x0
Software Reset.
0x0 = Normal Operation.
0x1 = Soft reset. This mode resets the digital portion of the PHY and
all of the registers. This bit self clears after completion.
14
SWRESTART
R/W
0x0
Software Restart.
0x0 = Normal Operation.
0x1 = Restart PHY. This mode resets the digital portion of the PHY
but no the registers. This bit self clears after completion of the
restart.
13-0
RESERVED
R