SCI Control Registers
1358
SPNU503C – March 2018
Copyright © 2018, Texas Instruments Incorporated
Serial Communication Interface (SCI) Module
26.7.12 SCI Data Buffers (SCIED, SCIRD, SCITD)
The SCI has three addressable registers in which transmit and receive data is stored.
26.7.12.1 Receiver Emulation Data Buffer (SCIED)
The SCIED register is addressed at a location different from SCIRD, but is physically the same register.
and
illustrate this register.
Figure 26-19. Receiver Emulation Data Buffer (SCIED) [offset = 30h]
31
16
Reserved
R-0
15
8
7
0
Reserved
ED
R-0
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 26-18. Receiver Emulation Data Buffer (SCIED) Field Descriptions
Bit
Field
Value
Description
31-8
Reserved
0
Reads return 0. Writes have no effect.
7-0
ED
0-FFh
Emulator data. Reading SCIED[7:0] does not clear the RXRDY flag, unlike reading SCIRD. This
register should be used only by an emulator that must continually read the data buffer without
affecting the RXRDY flag.
26.7.12.2 Receiver Data Buffer (SCIRD)
This register provides a location for the receiver data.
and
illustrate this register.
NOTE:
When the SCI receives data that is fewer than eight bits in length, it loads the data into this
register in a left-justified format padded with trailing zeros. Therefore, the user software
should perform a logical shift on the data by the correct number of positions to make it right
justified.
Figure 26-20. Receiver Data Buffer (SCIRD) [offset = 34h]
31
16
Reserved
R-0
15
8
7
0
Reserved
RD
R-0
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 26-19. Receiver Data Buffer (SCIRD) Field Descriptions
Bit
Field
Value
Description
31-8
Reserved
0
Reads return 0. Writes have no effect.
7-0
RD
0-FFh
Receiver data. When a frame has been completely received, the data in the frame is transferred
from the receiver shift register SCIRXSHF to this register. As this transfer occurs, the RXRDY flag
is set and a receive interrupt is generated if SET RX INT is set.
Note: When the data is read from SCIRD, the RXRDY flag is automatically cleared.