PRODUCTPREVIEW
RM46L852
SPNS185 – SEPTEMBER 2012
Table 2-18. PGE System Module Interface (continued)
Terminal
Signal
Default
Pull Type
Description
Type
Pull State
Signal Name
144
PGE
nERROR
117
I/O
Pull Down
20uA
ESM Error Signal
Indicates error of high
severity. See
.
2.3.1.16 Clock Inputs and Outputs
Table 2-19. PGE Clock Inputs and Outputs
Terminal
Signal
Default
Pull Type
Description
Type
Pull State
Signal Name
144
PGE
OSCIN
18
Input
-
-
From external
crystal/resonator, or
external clock input
KELVIN_GND
19
Input
Kelvin ground for oscillator
OSCOUT
20
Output
To external
crystal/resonator
ECLK
119
I/O
Pull Down
Programmable,
External prescaled clock
20uA
output, or GIO.
GIOA[5]/EXTCLKIN/EPWM1A /N2HET1_PIN_nDIS
14
Input
Pull Down
20uA
External clock input #1
2.3.1.17 Test and Debug Modules Interface
Table 2-20. PGE Test and Debug Modules Interface
Terminal
Signal
Default
Pull Type
Description
Type
Pull State
Signal Name
144
PGE
TEST
34
Input
Pull Down
Fixed, 100uA
Test enable
nTRST
109
Input
JTAG test hardware reset
RTCK
113
Output
-
-
JTAG return test clock
TCK
112
Input
Pull Down
Fixed, 100uA
JTAG test clock
TDI
110
Input
Pull Up
JTAG test data in
TDO
111
Output
Pull Down
JTAG test data out
TMS
108
Input
Pull Up
JTAG test select
2.3.1.18 Flash Supply and Test Pads
Table 2-21. PGE Flash Supply and Test Pads
Terminal
Signal
Default
Pull Type
Description
Type
Pull State
Signal Name
144
PGE
VCCP
134
3.3V
-
-
Flash pump supply
Power
FLTP1
7
-
-
-
Flash test pads. These
terminals are reserved for
FLTP2
8
TI use only. For proper
operation these terminals
must connect only to a
test pad or not be
connected at all [no
connect (NC)].
22
Device Package and Terminal Functions
Copyright © 2012, Texas Instruments Incorporated
Содержание RM46L852
Страница 170: ......