August 2001
Series 7000 Reader Reference Guide
24
Draft Document
FCC ID: A92RU1001A
-
Thermal Shock: Thermal Shock testing in accordance with MIL-STD-810E, Method 503.3,
using the following thermal shock parameters: - 45 to 85 degrees C, 100 cycles duration, 30
minutes per temperature.
-
Mechanical Shock Environment: Shock test performed in accordance with MIL-STD-810E,
Method 516.3 using the following parameters: 5 G's at 10 ms, half-sinusoidal wave, 6 axes,
and 3 shocks per axis.
-
Vibration Environment: Vibration tests in accordance with MIL-STD-810E, Method 514.4,
using the following parameters: 15 to 500 Hz, 1-g peak, 30 minutes sweep, logarithmic.
4.5 Warranty and Liability
The "General Conditions of Sale and Delivery" of Texas Instruments Incorporated or a TI
subsidiary apply. Warranty and liability claims for defect products, injuries to persons and
property damages are void if they are the result of one or more of the following causes:
!
Improper use of the reader module.
!
Unauthorized assembly, operation and maintenance of the reader module.
!
Operation of the reader modules with defective and/or non-functioning safety and
protective equipment.
!
Failure to observe the instructions during transport, storage, assembly, operation,
maintenance and setting up of the reader modules.
!
Unauthorized changes to the reader modules.
!
Insufficient monitoring of the reader modules' operation or environmental conditions.
!
Improperly conducted repairs.
!
Catastrophes caused by foreign bodies and acts of God.