1
AES Transponder User Interface
Figure 15. RF430F5978EVM AES Transponder Tab 2
1. MRD2 Command:
User input interface for setup direct hex commands
Example: Set default timing "BLC (Automotive) Timing (Command 0x0D)"
01 12 83 0D 00 AA 01 CC 00 AA 00 E6 00 AA 01 5E 00 AA 02 44 AE
Detailed Information in Microreader RI-STU-MRD2 Reference Guide (
). (See Section 6.4.3.14)
2. Predefined Commands:
Switch to wake up timing:
"Special wake up timing (Command 0x0D)"
01 12 83 0D 00 AA 03 E8 00 AA 00 FA 00 AA 02 8A 00 AA 27 10 32
SOFoff
170 µs
SOFon
1000 µs
toffLow
170 µs
tonLow
250 µs
toffHigh
170 µs
tonHigh
650 µs
EOFoff
170 µs
EOFon
10000 µs
Switch to default timing:
"BLC (Automotive) Timing (Command 0x0D)"
01 12 83 0D 00 AA 01 CC 00 AA 00 E6 00 AA 01 5E 00 AA 02 44 AE
17
SLRU007 – July 2014
RF430F5978EVM User Guide
Copyright © 2014, Texas Instruments Incorporated