Testing the PGA5807A EVM
Figure 41. HSDCpro GUI Setup
4. The plot will update as shown in
. Take note of the
Fund.
value in the left panel highlighted in
RED in
. This value is dependent on the signal level set on the signal generator feeding the
input signal to
J36
. It also depends on cable loss and filter insertion loss which can vary among parts.
If needed, reset the signal amplitude (level) until the
Fund.
value is approximately –1.0 dBFs, as this is
the condition for which the datasheet specifications are set. The input level was iteratively adjusted to
achieve –1.0 dBFs as seen in
Figure 42. ADS5296A Only Sinusoidal Capture 1
31
SLAU538 – October 2013
PGA5807A, 8-Channel, High-Bandwidth, Analog Front-End Evaluation
Module
Copyright © 2013, Texas Instruments Incorporated