19
Using the Demonstration Software
2.3.1 HOLD and PASS
Near the top of each window, there is a small button. This button is labeled either
HOLD
or
PASS
. You
can toggle the current setting by clicking on this button. When set to HOLD, the settings in an active
window can be changed, but are not written to the register(s) until you press the OK button that appears at
the bottom of the screen.
When the button is set to PASS, any setting changes made in an active window are immediately written to
the corresponding register(s).
2.3.2 Applicable Function Control
summarizes the various functions of the DEM-DAI1681 and the default settings for each
function. Note that the software is also designed to control the DEM-DAI1608 as well as the
DEM-DAI1681; therefore, there are several inconsistencies between the demonstration software and the
also describes these differences between the software of
DEM-DAI1681 and PCM1681 in detail.
Table 2-1. Applicable Function Control Summary
Function
PCM1681 Default Setting
Availability on DEM-DAI1681
Digital Attenuation Control, 0 dB to –63 dB
in 0.5-dB Steps
0 dB, No Attenuation
Applicable
Soft Mute Control
Mute Disabled
Applicable
DAC1–8 Operation Control
DAC1–8 Enabled
Applicable
Audio Data Format Control
16-Bit to 24-Bit Left-Justified
Partly Applicable
(1)
Digital Filter Roll-Off Control
Sharp Roll-Off
Applicable
De-Emphasis All Channel Function
Control
De-Emphasis All Channel Disabled
Applicable
De-Emphasis All Channel Sample Rate
Selection
44.1 kHz
Applicable
Output Phase Select
Normal Phase
Applicable
Zero Flag Polarity Select
High
Applicable
Software Reset Control
Reset Disabled
Not Applicable
Output Phase Select per Channel
Reverse Phase
Not Applicable
Oversampling Rate Control
Narrow (x64, x32, x16) mode
Applicable
Digital Filter Roll-Off Control per DATA
Group
Slow Roll-Off
Not Applicable
Zero Flag Combination Select
ZR1: DATA1 Lch
ZR2: DATA1 Rch
Not Applicable
Digital Attenuation Mode Select
0 to –63 dB, 0.5-dB step
Not Applicable
Zero Detect Status
(Read-only, I
2
C Interface Only)
Not Applicable
Not Applicable
Function
DEM-DAI1681 Default Setting
Availability on PCM1681
SCKO Frequency Selection and Output
Enable Control
Enabled as SCKO = SCKI
Not Applicable
GPO Output Set and Control
Enabled as Zero Flags, not GPOs
Not Applicable
Register Read and Address Control
Enabled without Auto-Increment
Not Applicable
(1)
There is a difference betwen applicable formats and default setting.
Содержание PCM1681
Страница 1: ...DEM DAI1681 PCM1681 Evaluation Module User s Guide Literature Number SBAU137 April 2008 ...
Страница 2: ...Submit Documentation Feedback 2 SBAU137 April 2008 ...
Страница 6: ...Submit Documentation Feedback 6 List of Tables SBAU137 April 2008 ...
Страница 20: ...Submit Documentation Feedback 20 Demonstration Software SBAU137 April 2008 ...
Страница 26: ...Submit Documentation Feedback 26 Typical Performance and Measurement Examples SBAU137 April 2008 ...