OPT3004EVM Software
14
SBOU220 – December 2018
Copyright © 2018, Texas Instruments Incorporated
OPT3004EVM User's Guide
There is a data logging feature included in the software, as shown in
. This feature allows the
user to record the date and time from the host computer, along with the measured lux value reported by
the device. After a destination file is selected by clicking
Select a File/Path
, turning on the
Logging On/Off
selector switch appends data to that file in .tab format.
Figure 19. Data Logging Setup and Enable
Under the final tab,
Register Map
, shown in
, there is a button labeled
Read All
. Clicking this
button reads registers x00 through x0F and displays the results to the
Register Table
spreadsheet. In this
way, all register values, including the values of x0E and x0F, can be easily verified to match the values
shown in the data sheet.
Figure 20. Read All Button on the Register Map Tab with Example Output