Measurement Setup
www.ti.com
6
SLLU256 – October 2016
Submit Documentation Feedback
Copyright © 2016, Texas Instruments Incorporated
ONET1131EC Evaluation Module
4
Measurement Setup
Follow this procedure to quickly set up to take measurements:
1. Install the ONET1130EC GUI onto the computer and follow the installation instructions.
2. Solder the TOSA onto the EVM.
3. Connect a differential data input signal source to the SMA connectors TXINP/TXINN through 50-
Ω
matched impedance cables. Set the data rate between 9.8 Gbps and 11.7 Gbps. Set the amplitude
between 100 mVp-p differential and 1000 mVp-p differential.
4. Connect the USB dongle to the EVM and attach the interface cable from the USB port of the computer
to the mini-B USB port of the dongle.
5. Apply a 2.5-V supply to the +2.5-V banana jack and the supply ground to the GND banana jack.
6. Apply a negative bias voltage in the range of –0.4 V to –1.5 V for the EML to JMP28. The required
voltage is TOSA dependent.
7. Connect the TOSA thermistor at JMP24 to the TEC controller.
8. Connect the TEC+ and TEC– at JMP27 to the TEC controller.
9. Connect the TOSA to the optical input of a DCA through a single-mode fiber patch cord.
A typical setup is shown in
Figure 5
.
Figure 5. Typical Setup