ADC12 Operation
17-16
ADC12
17.2.8 Using the Integrated Temperature Sensor
To use the on-chip temperature sensor, the user selects the analog input
channel INCHx = 1010. Any other configuration is done as if an external
channel was selected, including reference selection, conversion-memory
selection, etc.
The typical temperature sensor transfer function is shown in Figure 17−10.
When using the temperature sensor, the sample period must be greater than
30
µ
s. The temperature sensor offset error can be large, and may need to be
calibrated for most applications. See device-specific datasheet for
parameters.
Selecting the temperature sensor automatically turns on the on-chip reference
generator as a voltage source for the temperature sensor. However, it does not
enable the V
REF+
output or affect the reference selections for the conversion.
The reference choices for converting the temperature sensor are the same as
with any other channel.
Figure 17−10. Typical Temperature Sensor Transfer Function
Celsius
Volts
0
50
100
1.000
0.800
0.900
1.100
1.200
1.300
−50
0.700
VTEMP=0.00355(TEMPC)+0.986
Содержание MSP430x1xx
Страница 1: ... 2005 Mixed Signal Products User s Guide SLAU049E ...
Страница 6: ...vi ...
Страница 18: ...1 6 Introduction ...
Страница 36: ...2 18 System Resets Interrupts and Operating Modes ...
Страница 112: ...3 76 ...
Страница 130: ...4 18 Basic Clock Module ...
Страница 152: ...5 22 Flash Memory Controller ...
Страница 160: ...6 8 Supply Voltage Supervisor ...
Страница 168: ...7 8 Hardware Multiplier ...
Страница 192: ...8 24 ...
Страница 200: ...9 8 Digital I O ...
Страница 234: ...11 24 Timer_A ...
Страница 260: ...12 26 Timer_B ...
Страница 291: ...13 31 USART Peripheral Interface UART Mode ...
Страница 314: ...14 23 USART Peripheral Interface SPI Mode ...
Страница 346: ...15 32 USART Peripheral Interface I2C Mode ...
Страница 358: ...16 12 Comparator_A ...
Страница 386: ...17 28 ADC12 ...
Страница 418: ...18 32 ADC10 ...
Страница 432: ...19 14 DAC12 ...