8 Bill of Materials (BOM)

Table 8-1

 lists the LM66200EVM BOM.

Table 8-1. LM66200EVM BOM

Designator

Quantity

Value

Description

Package Reference

Part Number

Manufacturer

C1, C4, C10

3

100 uF

CAP, CERM, 100 uF, 16
V, +/- 20%, X5R, 1210

1210

C1210C107M4PAC7800

Kemet

C2, C5, C9

3

10 uF

CAP, CERM, 10 µF, 20
V,+/- 10%, X5R, 0805

0805

GRM21BR61D106KE15L MuRata

C3, C6

2

0.1 uF

CAP, CERM, 0.1 uF, 25 V,
+/- 10%, X7R, 0603

0603

06033C104KAT2A

AVX

C7

1

0.1 uF

CAP, CERM, 0.1 uF, 25 V,
+/- 5%, X7R, 0805

0805

08053C104JAT2A

AVX

C8

1

1 uF

CAP, CERM, 1 uF, 50 V,
+/- 10%, X7R, 0805

0805

C0805C105K5RACTU

Kemet

H9, H10, H11, H12

4

Bumpon, Hemisphere,
0.44 X 0.20, Clear

Transparent Bumpon

SJ-5303 (CLEAR)

3M

J1, J3, J4

3

Standard Banana Jack,
insulated, 10A, red

571-0500

571-0500

DEM Manufacturing

J2, J5

2

Standard Banana Jack,
insulated, 10A, black

571-0100

571-0100

DEM Manufacturing

JP1

1

Header, 100mil, 3x1, TH

Header, 3x1, 100mil, TH

800-10-003-10-001000

Mill-Max

JP2, JP3, JP4, JP5

4

Header, 100mil, 2x1, Tin,
TH

Header, 2 PIN, 100mil,
Tin

PEC02SAAN

Sullins Connector
Solutions

R1

1

5.00 k

RES, 5.00 k, 0.1%, 0.2 W,
0805

0805

PNM0805E5001BST5

Vishay Thin Film

R2

1

10.0 k

RES, 10.0 k, 0.5%, 0.1 W,
0603

0603

RT0603DRE0710KL

Yageo America

R3

1

10.0

RES, 10.0, 1%, 16 W,
2512

2512

CPA2512Q10R0FS-T10

Susumu Co Ltd

SH-J1, SH-J2, SH-J3,
SH-J4, SH-J5

5

1x2

Shunt, 100mil, Flash
Gold, Black

Closed Top 100mil Shunt SPC02SYAN

Sullins Connector
Solutions

TP1, TP2, TP3, TP4,
TP5, TP6

6

Test Point, Multipurpose,
Red, TH

Red Multipurpose
Testpoint

5010

Keystone

www.ti.com

Bill of Materials (BOM)

SLVUC50 – APRIL 2021

Submit Document Feedback

LM66200 Evaluation Module

7

Copyright © 2021 Texas Instruments Incorporated

Содержание LM66200EVM

Страница 1: ...Setting up the LM66200EVM 6 7 Test Configuration 6 8 Bill of Materials BOM 7 Revision History 9 List of Figures Figure 4 1 LM66200EVM Schematic 4 Figure 5 1 LM66200 Top Layer 5 Figure 5 2 LM66200 Bottom Layer 5 Figure 7 1 LM66200 Setup With Test Equipment 6 List of Tables Table 1 1 LM66200 Modes of Operation 2 Table 3 1 LM66200EVM Input and Output Connector Functionality 3 Table 3 2 LM66200EVM Tes...

Страница 2: ... operation of the LM66200 Table 1 lists the different modes of operation For additional details on ideal diodes and the data sheet see Ideal diode OR ing Controllers on TI com Table 1 1 LM66200 Modes of Operation EVM Device Modes of Operation VOUT Range IOUT MAX LM66200EVM LM66200 Diode highest voltage operation 1 6 V 5 5 V 2 5 A 1 2 Features This EVM has the following features 1 6 V 5 5 V voltage...

Страница 3: ...2 SENSE test point VOUT J4 VOUT VOUT output connector TP5 VOUT SENSE VOUT SENSE test point TP6 VOUT VOUT output test point GND J2 GND GND connector for inputs J5 GND GND connector for output TP9 TP10 TP11 TP12 GND Test point for GND Table 3 2 LM66200EVM Test Point Description Input Test point Label Description VOUT TP7 ST Output status pin test point VIN1 TP8 ON Enable pin for LM66200 Table 3 3 LM...

Страница 4: ... GND GND GND GND 10µF C2 10µF C5 GND GND 1uF C8 10µF C9 100uF C10 GND GND GND GND 1 2 JP2 1 2 JP3 1 2 JP4 1 2 JP5 10 0 R3 0 1uF C7 J4 J3 J1 J5 J2 TP1 TP2 TP3 TP4 TP5 TP6 TP9 TP12 TP11 TP10 10 0k R2 TP8 TP7 VIN1 3 VIN2 6 VOUT 2 VOUT 7 ON 4 ST 8 GND 1 GND 5 LM66200DRLR U1 1 2 3 JP1 5 00k R1 ON VIN2 ON Figure 4 1 LM66200EVM Schematic Schematic www ti com 4 LM66200 Evaluation Module SLVUC50 APRIL 2021...

Страница 5: ...how the LM66200EVM PCB layout images Figure 5 1 LM66200 Top Layer Figure 5 2 LM66200 Bottom Layer www ti com PCB Layout SLVUC50 APRIL 2021 Submit Document Feedback LM66200 Evaluation Module 5 Copyright 2021 Texas Instruments Incorporated ...

Страница 6: ...M66200EVM has the default jumper settings described in Table 5 Table 6 1 Default Jumper Settings Jumper Description Position JP1 Sets ON pin reference Position 2 and 3 for VIN1 tied to ON Position 1 and 2 for VIN2 tied to ON JP2 1 μF Install JP2 for 1 uF of output capacitance JP5 10 Ω Install JP5 for 10 Ω of load resistance 7 Test Configuration Figure 4 shows the test equipment setup for the LM662...

Страница 7: ...1 0500 DEM Manufacturing J2 J5 2 Standard Banana Jack insulated 10A black 571 0100 571 0100 DEM Manufacturing JP1 1 Header 100mil 3x1 TH Header 3x1 100mil TH 800 10 003 10 001000 Mill Max JP2 JP3 JP4 JP5 4 Header 100mil 2x1 Tin TH Header 2 PIN 100mil Tin PEC02SAAN Sullins Connector Solutions R1 1 5 00 k RES 5 00 k 0 1 0 2 W 0805 0805 PNM0805E5001BST5 Vishay Thin Film R2 1 10 0 k RES 10 0 k 0 5 0 1...

Страница 8: ...1 TP12 4 Test Point Multipurpose Black TH Black Multipurpose Testpoint 5011 Keystone U1 1 1 6 V to 5 V 2 5 A Dual Ideal Diode with Automatic Switchover FCSOT8 LM66200DRLR Texas Instruments FID1 FID2 FID3 0 Fiducial mark There is nothing to buy or mount N A N A N A Bill of Materials BOM www ti com 8 LM66200 Evaluation Module SLVUC50 APRIL 2021 Submit Document Feedback Copyright 2021 Texas Instrumen...

Страница 9: ...visions may differ from page numbers in the current version DATE REVISION NOTES April 2021 Initial Release www ti com Revision History SLVUC50 APRIL 2021 Submit Document Feedback LM66200 Evaluation Module 9 Copyright 2021 Texas Instruments Incorporated ...

Страница 10: ...other than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control techniques are used to the extent TI deems necessary TI does not test all parameters of each EVM User s claims against TI under this Section 2 are void if User fails to notify TI of any apparent defects...

Страница 11: ... These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation...

Страница 12: ...y for convenience and should be verified by User 1 Use EVMs in a shielded room or any other test facility as defined in the notification 173 issued by Ministry of Internal Affairs and Communications on March 28 2006 based on Sub section 1 1 of Article 6 of the Ministry s Rule for Enforcement of Radio Law of Japan 2 Use EVMs only after User obtains the license of Test Radio Station as provided in R...

Страница 13: ... any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electrical shock hazard User assumes all responsibility and liability for any improper or unsafe handling or use of the EVM by User or its employees affiliates contractors or designees 4 4 User assumes all...

Страница 14: ...OR DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthermore no return of EVM s will be accepted if the package has been opened and no return of the EVM s will be accepted if they are damaged or otherwise not in a resalable condition If User feels it has...

Страница 15: ...s are subject to change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reproduction and display of these resources is prohibited No license is granted to any other TI intellectual property right or to any third party intellectual property right TI disclaims responsibility for and you wi...

Отзывы: