6 Test Setup
This chapter describes the default jumper test setup for the evalution of the LM66200 using the evaluation
module.
6.1 LM66200EVM Test Equipment
Read the LM66200 data sheet before using the EVM.
The following test equipment is recommended:
• Two adjustable power supplies, 0 V–6 V at 2.5-A maximum
• Oscilloscope
• A passive or active load
6.2 Setting up the LM66200EVM
Make sure the LM66200EVM has the default jumper settings described in
.
Table 6-1. Default Jumper Settings
Jumper
Description
Position
JP1
Sets ON pin reference
Position 2 and 3 for VIN1 tied to ON
Position 1 and 2 for VIN2 tied to ON
JP2
1 μF
Install JP2 for 1 uF of output
capacitance
JP5
10 Ω
Install JP5 for 10 Ω of load
resistance
7 Test Configuration
shows the test equipment setup for the LM66200EVM.
Figure 7-1. LM66200 Setup With Test Equipment
Test Setup
6
LM66200 Evaluation Module
SLVUC50 – APRIL 2021
Copyright © 2021 Texas Instruments Incorporated