General Configuration and Description
Table 4. Switches
Switch
Label
Description
S1
EN
Enable and disable of the hotswap
SW1
RETRY
Fault retry input
SW2
CL
Current limit range
SW3
ADR0
SMBus address line 0
SW4
ADR1
SMBus address line 1
SW5
ADR2
SMBus address line 2
3.2
Equipment Setup
1. Set the input power supply voltage to the desired operating input voltage.
2. Turn the power supply off.
3. Connect the positive voltage lead from the power supply to J1 (VIN). Connect the ground lead form the
power supply to J2 (GND).
4. Place a voltmeter or oscilloscope probe across J3 and J4 (VOUT).
4
Operation
1. Turn on the power supply.
2. Enable S1 ON.
3. Vary the input voltage and add load current as necessary for test purposes.
4. Apply fault conditions to observe fault performance as necessary.
6
LM5066IEVM-626 Evaluation Module (EVM)
SNVU444 – May 2014
Copyright © 2014, Texas Instruments Incorporated