![Texas Instruments LM25180-Q1 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/texas-instruments/lm25180-q1/lm25180-q1_user-manual_1095349006.webp)
A
COM
Ammeter 3
V
Voltmeter 3
COM
V
Voltmeter 2
COM
Oscilloscope
+
-
Power Supply
A
COM
Ammeter 1
+
-
A
COM
Ammeter 2
E-Load 2
V
Voltmeter 1
COM
+
-
E-Load 1
Test Setup and Procedure
6
SNVU609B – October 2018 – Revised April 2020
Copyright © 2018–2020, Texas Instruments Incorporated
LM5180-Q1 Dual-Output EVM User's Guide
5
Test Setup and Procedure
5.1
Test Setup
Table 3. EVM Connections
LABEL
DESCRIPTION
VIN+
Positive input voltage power and sense connection
VIN–
Negative input voltage power and sense connection
VOUT1
Output #1 power and sense connection
VOUT2
Output #2 power and sense connection
S-GND
Output return and sense connection
EN
ENABLE input – tie to GND to disable converter
SS/BIAS
External BIAS input
SW
SW node connection
Referencing the EVM connections described in
, the recommended test setup to evaluate the
LM5180EVM-DUAL is shown in
. Working at an ESD-protected workstation, make sure that any
wrist straps, boot straps, or mats are connected and referencing the user to earth ground before power is
applied to the EVM.
Figure 3. EVM Test Setup
SPACER
CAUTION
Refer to the
and
data sheets,
, and
for additional guidance pertaining
to component selection and converter operation.