Texas Instruments INA223EVM Скачать руководство пользователя страница 25

Evaluation Board/Kit Important Notice

Texas Instruments (TI) provides the enclosed product(s) under the following conditions:

This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES
ONLY 
and is not considered by TI to be a finished end-product fit for general consumer use. Persons handling the product(s) must have
electronics training and observe good engineering practice standards. As such, the goods being provided are not intended to be complete
in terms of required design-, marketing-, and/or manufacturing-related protective considerations, including product safety and environmental
measures typically found in end products that incorporate such semiconductor components or circuit boards. This evaluation board/kit does
not fall within the scope of the European Union directives regarding electromagnetic compatibility, restricted substances (RoHS), recycling
(WEEE), FCC, CE or UL, and therefore may not meet the technical requirements of these directives or other related directives.

Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days from
the date of delivery for a full refund. THE FOREGOING WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO BUYER
AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.

The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims
arising from the handling or use of the goods. Due to the open construction of the product, it is the user’s responsibility to take any and all
appropriate precautions with regard to electrostatic discharge.

EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY
INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.

TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive.

TI assumes no liability for applications assistance, customer product design, software performance, or infringement of patents or
services described herein.

Please read the User’s Guide and, specifically, the Warnings and Restrictions notice in the User’s Guide prior to handling the product. This
notice contains important safety information about temperatures and voltages. For additional information on TI’s environmental and/or
safety programs, please contact the TI application engineer or visit

www.ti.com/esh

.

No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or
combination in which such TI products or services might be or are used.

FCC Warning

This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES
ONLY 
and is not considered by TI to be a finished end-product fit for general consumer use. It generates, uses, and can radiate radio
frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC rules, which are
designed to provide reasonable protection against radio frequency interference. Operation of this equipment in other environments may
cause interference with radio communications, in which case the user at his own expense will be required to take whatever measures may
be required to correct this interference.

EVM Warnings and Restrictions

It is important to operate this EVM within the input voltage range of 0 V to 26 V and the output voltage range of 0 V to 5.5 V.

Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM. If there are questions
concerning the input range, please contact a TI field representative prior to connecting the input power.

Applying loads outside of the specified output range may result in unintended operation and/or possible permanent damage to the EVM.
Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification,
please contact a TI field representative.

During normal operation, some circuit components may have case temperatures greater than +25°C. The EVM is designed to operate
properly with certain components above +25°C as long as the input and output ranges are maintained. These components include but are
not limited to linear regulators, switching transistors, pass transistors, and current sense resistors. These types of devices can be identified
using the EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during operation,
please be aware that these devices may be very warm to the touch.

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265

Copyright © 2012, Texas Instruments Incorporated

Содержание INA223EVM

Страница 1: ...garding operating procedures and input output connections an electrical schematic printed circuit board PCB layout drawings and a parts list for the EVM Throughout this document the terms evaluation b...

Страница 2: ...Install Window 12 12 Software License Agreement 13 13 Software Install Progress 13 14 INA223EVM Software Interface 14 15 Communication Error with SM USB DIG Platform 14 16 Setting the A0 Address 15 1...

Страница 3: ...ile using this evaluation module 1 1 INA223EVM Kit Contents The INA223EVM kit includes the following items 1 INA223 PCB evaluation board 1 SM USB DIG Platform PCB 1 USB extender cable 1 SM USB DIG con...

Страница 4: ...477 8924 or the Product Information Center at 972 644 5580 When ordering identify the document by both title and literature number Table 1 Related Documentation Document Literature Number INA223 Produ...

Страница 5: ...SB DIG It should be noted that to issue commands to the INA223 chip the INA223EVM only uses H1 connnector pins 1 and 3 I2 C communication lines pin 6 VDUT and pin 8 GND Table 2 INA223EVM H1 Pin Connec...

Страница 6: ...e details of its operation are included in a separate document SBOU098 The block diagram shown in Figure 4 is given as a brief overview of the SM USB DIG Platform Figure 4 SM USB DIG Platform Block Di...

Страница 7: ...together gently slide the male and female ends of the 10 pin connectors together Make sure that the two connectors are completely pushed together loose connections may cause intermittent operation 3 3...

Страница 8: ...of with Microsoft Windows operating systems Figure 6 Connecting the USB Cable to the SM USB DIG Platform In some cases the Windows Add Hardware Wizard is shown If this prompt appears allow the system...

Страница 9: ...r example if JMP1 is connected do not connect JMP2 and vice versa Failure to properly connect jumpers can cause shorts or interruptions in the communication lines For more information on the INA223 ad...

Страница 10: ...t to either the SCL or SDA communication line Make sure to only have a jumper installed on JMP1 or JMP2 Failure to keep these lines separate can lead to board shorts and problems with the I2 C communi...

Страница 11: ...limit the value for R3 and R4 to 10 or less Figure 9 shows the typical setup that is recommended for basic INA223 evaluation See the INA223 data sheet SBOS528 for more details Figure 9 Typical Filter...

Страница 12: ...eb site To download the software to your system insert the disc into an available CD ROM drive Navigate to the drive contents and open the INA223EVM software folder Locate the compressed file INA223EV...

Страница 13: ...that must be accepted as shown in Figure 12 Figure 12 Software License Agreement After accepting the Texas Instruments and National Instruments license agreements the progress bar opens and shows the...

Страница 14: ...that appears if the computer cannot communicate with the EVM In the event you receive this error first ensure that the USB cable is properly connected on both ends This error can also occur if you con...

Страница 15: ...SCL the INA223 can be changed to four different I2 C addresses as shown in Table 4 Table 4 INA223 I2 C Address Configuration A0 Address GND 1000000 VS 1000001 SDA 1000010 SCL 1000011 Figure 16 shows...

Страница 16: ...ined with the VSHUNT measurement to calculate the power being supplied The Load Power option operates in a similar manner to the Supply Power option except that the VBUS measurement is taken internall...

Страница 17: ...1 5 20 1 333 1 5 128 8 533 1 5 300 20 2 5 20 2 667 2 5 128 17 067 2 5 300 40 The remaining two configurations Bus Voltage and Shunt Voltage measure the bus voltages at the VIN pin and the shunt volta...

Страница 18: ...igure 18 Configuring the Bus Voltage Gain 5 2 4 Current Shunt Voltage Gain The Current Shunt Voltage Gain field is used to select the device shunt voltage gain setting It is important to choose a valu...

Страница 19: ...control of the part outside the general functionality of the graphical user interface GUI Most of this functionality is displayed in the Configuration Register however by selecting the appropriate re...

Страница 20: ...er and Voltage Controls The software also includes an Auto Write feature as shown in the lower red box in Figure 21 Auto Write is enabled by default and automatically updates the register table whenev...

Страница 21: ...in the Error field This calculator is used to help ensure that the physical output and settings are operating correctly The EVM and device digital communication interface are only designed to configu...

Страница 22: ...1 10W 0603 SMD Stackpole Electronics RMCF0603ZT0R00CT ND RMCF0603ZT0R00 C2 CAP TANTALUM 4 7UF 35V 10 SM AVX Corp 478 1717 1 ND TAJC475K035RNJ C3 C4 CAP CER 10UF 25V X7R 10 0603 TDK Corp 445 1316 1 ND...

Страница 23: ...6 7 8 6 www ti com INA223EVM Documentation 6 2 Schematic Figure 23 shows the schematic for the INA223EVM board Figure 23 INA223EVM Board Schematic 23 SBOU125 June 2012 INA223EVM User s Guide and Softw...

Страница 24: ...yout Figure 24 shows the layout of the components for the INA223EVM PCB Figure 24 INA223EVM PCB Component Layout 24 INA223EVM User s Guide and Software Tutorial SBOU125 June 2012 Submit Documentation...

Страница 25: ...oduct This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application engine...

Страница 26: ...or use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury or death unless officers of the parties have...