10 Typical Connection and Test Equipment
The following is a list of typical test equipment that may be used to monitor the MIPI CSI-2 signals from the
DS90UB960-Q1:
1. Logic Analyzer
2. Any SCOPE with a bandwidth of at least 4 GHz for observing differential signals.
3. UNH-IOL MIPI D-PHY Reference Termination Board (RTB)
4. UNH-IOL MIPI D-PHY/CSI/DSI Probing Board
5. UNH-IOL CSIGUI Tool
11 Termination Device
A termination device is required to properly monitor and measure the transmission of the MIPI DPHY signals.
The termination device must support the change of signals as it switches between LP and HS modes. This
can be provided by either a CSI-2 receiver or a dedicated dynamic termination board. TI recommends the
termination board is the UNH-IOL MIPI D-PHY Reference Termination Board (RTB).
12 Typical Test Setup
illustrate the typical test setups used to measure and evaluate DS90UB96X-Q1.
DS90UB960
EVM Board
Contents of Demo Kit
FPD-Link III + PoC
Camera
Serializer Board
MIPI CSI-2
Applications
Processor
Display
Figure 12-1. Typical Test Setup for Application
The picture below shows a typical test set up using a video generator and logic analyzer.
MIPI CSI-2
Logic Analyzer / Oscilloscope
Camera
Serializer Board
DS90UB960
EVM Board
Contents of Demo Kit
FPD-Link III + PoC
Figure 12-2. Typical Test Setup for Evaluation
Typical Connection and Test Equipment
SNLU226B – FEBRUARY 2018 – REVISED APRIL 2021
DS90UB960-Q1EVM User's Guide
27
Copyright © 2021 Texas Instruments Incorporated