Factory Set Switch Settings and Jumpers Default Configuration
10
SNLU135B – June 2013 – Revised April 2016
Copyright © 2013–2016, Texas Instruments Incorporated
Board Setup Details
2.5.2 Deserializer Board Default Configuration
S1, S2, JP6, JP12 of Deserializer board are factory configured as shown in
for plug and play
operation.
1. The S1 switch is factory set as shown below in
(a) The PDN switch is set high and will turn on the Deserializer upon power up. This switch is
connected to PDB pin of the device.
(b) The OEN and OSS_SEL switch are set HIGH and will enable outputs to toggle upon power up.
(c) The SEL switch is set high to select RIN1+/- input, which feeds serial stream data to the device
from coax cable.
Refer to
for more details.
Figure 2-7. Switch S1: Default Settings on Deserializer Board
Table 2-1. Switch S1: Deserializer Board
Switch reference
Default Setting
Function
S1.1-PDN
High
High: Deserializer is enabled and is ON.
Low: Deserializer is in Sleep (power down mode). In this mode,
programmed control register data are NOT retained and reset to
default values.
S1.2-BISTEN
Low
High: BIST Mode Enabled
Low: BIST Mode Disabled
S1.3-OEN
High
Refer table on "Output States" in the device datasheet
S1.4-OSS SEL
S1.5-SEL
High
High: RIN1+/- input is selected as the active channel on the
Deserializer.
Low: RIN0+/- input is selected as the active channel on the
Deserializer.
S1.6-RES
Low
Reserved and must be set Low always.
S1.7-RES