Note 1: Only lower 4-channels shown
Note 2: Internal RX AC coupling capacitors
RX2P
RX2N
TX2P
TX2N
RX3P
RX3N
TX3P
TX3N
RX0P
RX0N
TX0P
TX0N
RX1P
RX1N
TX1P
TX1N
DS280MB810EVM
X
X
INPUT
CHANNELS
OUTPUT
CHANNELS
DATA
SOURCE
(up to 28 Gbps)
SCOPE
or
BERT
(up to 28 Gbps)
Example Hardware Test Setup
14
SNLU213A – October 2016 – Revised September 2019
Copyright © 2016–2019, Texas Instruments Incorporated
DS280MB810EVM User’s Guide
5
Example Hardware Test Setup
In order to test the functionality of the DS280MB810EVM, connect TXP0 and TXN0 with MXP cable
assemblies to DC blocking capacitors and a Keysight DCA-x Oscilloscope or equivalent (50
Ω
terminated).
Connect the data source, high speed BERT or other device with MXP cable assemblies to RXP0 and
RXN0. Add input and output channels as desired to emulate a system topology. Use the Jitter/Noise and
Eye/Mask functions on the Oscilloscope to view the output. The test set up can be seen below in
Figure 12. Example Test Set Up