Texas Instruments DS280DF810EVM Скачать руководство пользователя страница 26

STANDARD TERMS FOR EVALUATION MODULES

1.

Delivery:

TI delivers TI evaluation boards, kits, or modules, including any accompanying demonstration software, components, and/or

documentation which may be provided together or separately (collectively, an “EVM” or “EVMs”) to the User (“User”) in accordance
with the terms set forth herein. User's acceptance of the EVM is expressly subject to the following terms.

1.1

EVMs are intended solely for product or software developers for use in a research and development setting to facilitate feasibility
evaluation, experimentation, or scientific analysis of TI semiconductors products. EVMs have no direct function and are not
finished products. EVMs shall not be directly or indirectly assembled as a part or subassembly in any finished product. For
clarification, any software or software tools provided with the EVM (“Software”) shall not be subject to the terms and conditions
set forth herein but rather shall be subject to the applicable terms that accompany such Software

1.2

EVMs are not intended for consumer or household use. EVMs may not be sold, sublicensed, leased, rented, loaned, assigned,
or otherwise distributed for commercial purposes by Users, in whole or in part, or used in any finished product or production
system.

2

Limited Warranty and Related Remedies/Disclaimers

:

2.1

These terms do not apply to Software. The warranty, if any, for Software is covered in the applicable Software License
Agreement.

2.2

TI warrants that the TI EVM will conform to TI's published specifications for ninety (90) days after the date TI delivers such EVM
to User. Notwithstanding the foregoing, TI shall not be liable for a nonconforming EVM if (a) the nonconformity was caused by
neglect, misuse or mistreatment by an entity other than TI, including improper installation or testing, or for any EVMs that have
been altered or modified in any way by an entity other than TI, (b) the nonconformity resulted from User's design, specifications
or instructions for such EVMs or improper system design, or (c) User has not paid on time. Testing and other quality control
techniques

are

used

to

the

extent

TI

deems

necessary.

TI

does

not

test

all

parameters

of

each

EVM.

User's claims against TI under this Section 2 are void if User fails to notify TI of any apparent defects in the EVMs within ten (10)
business days after delivery, or of any hidden defects with ten (10) business days after the defect has been detected.

2.3

TI's sole liability shall be at its option to repair or replace EVMs that fail to conform to the warranty set forth above, or credit
User's account for such EVM. TI's liability under this warranty shall be limited to EVMs that are returned during the warranty
period to the address designated by TI and that are determined by TI not to conform to such warranty. If TI elects to repair or
replace such EVM, TI shall have a reasonable time to repair such EVM or provide replacements. Repaired EVMs shall be
warranted for the remainder of the original warranty period. Replaced EVMs shall be warranted for a new full ninety (90) day
warranty period.

WARNING

Evaluation Kits are intended solely for use by technically qualified,

professional electronics experts who are familiar with the dangers

and application risks associated with handling electrical mechanical

components, systems, and subsystems.

User shall operate the Evaluation Kit within TI’s recommended

guidelines and any applicable legal or environmental requirements

as well as reasonable and customary safeguards. Failure to set up

and/or operate the Evaluation Kit within TI’s recommended

guidelines may result in personal injury or death or property

damage. Proper set up entails following TI’s instructions for

electrical ratings of interface circuits such as input, output and

electrical loads.

NOTE:

EXPOSURE TO ELECTROSTATIC DISCHARGE (ESD) MAY CAUSE DEGREDATION OR FAILURE OF THE EVALUATION
KIT; TI RECOMMENDS STORAGE OF THE EVALUATION KIT IN A PROTECTIVE ESD BAG.

Содержание DS280DF810EVM

Страница 1: ...le power supply and minimal need for external components These features reduce PCB routing complexity and BOM cost The advanced equalization features of the DS280DF810 include a low jitter 3 tap trans...

Страница 2: ...the Selection Panel 6 5 Low Level Page Capture Illustrating the Different Block Select Options 7 6 Low Level Page Capture After Selecting Access to an Individual Register 7 7 Eye Monitor Page for DS2...

Страница 3: ...3V power 2A max as shown below The EVM has an on board 3 3V to 2 5V regulator to supply the Retimer with the required 2 5V Figure 1 DS280DF810EVM Showing Necessary Connections for Power Signal and US...

Страница 4: ...ww ti com tool sigconarchitect and download the latest version of SigCon Architect At the time this document was written the latest version of SigCon Architect is 2 0 0 4 Figure 2 Download SigCon Arch...

Страница 5: ...Go to Device tab and choose Manage Devices 2 Click on icon and then select the DS280DF810 device model 3 Fill in the New Device Name DS280DF810 is recommended 4 Select the slave address as configured...

Страница 6: ...own below The user may click Read All to load the data in each register from the device to the Register Map The user may access the Shared Global or Channel registers via Block Select To Read a regist...

Страница 7: ...019 Submit Documentation Feedback Copyright 2016 2019 Texas Instruments Incorporated DS280DF810EVM User s Guide Figure 5 Low Level Page Capture Illustrating the Different Block Select Options Figure 6...

Страница 8: ...a given channel if CDR Locked is indicated The EOM_SEL_VRANGE pull down allows the user to adjust the vertical scale for eye plots The user may perform a Single Capture of eye monitor plot or select...

Страница 9: ...tings are described in greater detail below Common Channel If this box is checked all channels receive the same configuration Different devices can receive different configurations but within one devi...

Страница 10: ...es Base Header of devices 8 Bytes device Address Header of slots 66 Bytes slot Data EEPROM Size 256 Bytes EEPROM Size 3 Bytes Base Header of devices 12 Bytes device Address Header of slots 66 Bytes sl...

Страница 11: ...R lock status is displayed Note that each channel s CDR status and configuration is independent from the others EQ Boost This field displays the Rx Continuous Time Linear Equalizer CTLE boost value as...

Страница 12: ...modes To do so the user should click on the desired adapt mode then click Apply to Channel to configure a specific retimer channel Alternatively the user may broadcast the new adapt mode setting by c...

Страница 13: ...nfigure the 2x2 cross point implemented for each of the adjacent channel pairs of the DS280DF810 retimer With the Pair Select pull down the user can choose which cross point pair to configure 0 1 2 3...

Страница 14: ...14A July 2016 Revised September 2019 Submit Documentation Feedback Copyright 2016 2019 Texas Instruments Incorporated DS280DF810EVM User s Guide Figure 12 Cross Point Tab Default Mode Selected Figure...

Страница 15: ...y the mode that the retimer is currently set to along with the data rate setting and also the divider setting in the case of Manual Mode Standard Mode allows the user to program the retimer rate sub r...

Страница 16: ...then see the manual mode input fields become adjustable Select the desired divider setting from the Divider Configuration pull down Select divide by 1 when data rate 13 Gbps Select divide by 2 when 1...

Страница 17: ...oftware Description 17 SNLU214A July 2016 Revised September 2019 Submit Documentation Feedback Copyright 2016 2019 Texas Instruments Incorporated DS280DF810EVM User s Guide Figure 16 CDR Tab Manual Mo...

Страница 18: ...rsor and post cursor equalization ratios Figure 17 TX FIR Tab Upon landing on the TX FIR tab the page will display the current decimal values and polarity for the main cursor post cursor and pre curso...

Страница 19: ...the High Level page allows the user to configure the PRBS generator or Checker functions on any of the channels of the DS280DF810 retimer To enable PRBS Generator on a channel Select the desired chann...

Страница 20: ...Period Set pull down to Infinite if it desired to run extended duration test without time limit If Finite period is desired set the pull down to Finite and enter the desired test duration via the Hou...

Страница 21: ...DR lock and status indicators to see if the link is established 3 If the CDR is in lock the CDR lock indicator on the page will turn green and display CDR locked 3 Check the Horizontal Eye Opening HEO...

Страница 22: ...rtion loss 35 dB at 12 9 GHz Crosstalk at victim RX 4 1 mV RMS 24 1 mVppd Victim TX amplitude 1200 mVppd Victim TX FIR C 1 4 C 0 24 C 1 3 Adapt mode 2 Adapted RX CTLE 3 0 0 0 Adapted DFE 0x14 0x2 0x1...

Страница 23: ...0 84 4 93 8 103 1 112 5 121 9 131 3 140 6 150 0 159 4 168 8 178 1 187 5 196 9 206 3 215 6 225 0 234 4 243 8 253 1 262 5 271 9 281 3 290 6 1 000 0 750 0 500 0 250 0 0 250 0 500 0 750 1 000 5 Supplement...

Страница 24: ...ere are three part numbers that TI suggests using with this EVM 1 85014420 MF53 1x8A_21MXP 21SMA 152 MXP 15 cable assembly This is a lower cost cable assembly compared to the MXP 40 but the SI perform...

Страница 25: ...t Documentation Feedback Copyright 2016 2019 Texas Instruments Incorporated Revision History Revision History NOTE Page numbers for previous revisions may differ from page numbers in the current versi...

Страница 26: ...ther than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control tec...

Страница 27: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in...

Страница 28: ...instructions set forth by Radio Law of Japan which includes but is not limited to the instructions below with respect to EVMs which for the avoidance of doubt are stated strictly for convenience and s...

Страница 29: ...any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electr...

Страница 30: ...R DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthe...

Страница 31: ...e resources are subject to change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reprod...

Отзывы: