Software Description
5
SNLU180C – August 2015 – Revised September 2019
Copyright © 2015–2019, Texas Instruments Incorporated
DS250DF810EVM User’s Guide
2. Run the SigCon Architect software.
1. Start the software by double-clicking its icon on the desktop.
2. On the “Selection” panel, the DS250DF810 should appear.
3. If DS250DF810 is not listed:
1. Go to “Device” tab and choose “Manage Devices”.
2. Click on “+” icon and then select the “DS250DF810” device model.
3. Fill in the “New Device Name, DS250DF810 is recommended.
4. Select the slave address as configured on EVM (typical setting is 0x30).
5. Click “OK”.
4. Navigate to the “Configuration” page of DS250DF810 via the “Selection” panel. Choose “Slave
Address” “0x30” from the drop down menu. Verify the “USB2ANY Details” specify “USB2ANY 0”,
and click “Apply”. Successful connection is indicated by the green “CONNECTED” indicator on the
bottom of the application.
Figure 3. Sigcon Architect Start-Up Screen