background image

www.ti.com

Operation of the EVM

9

SLVUBG7C – August 2018 – Revised December 2019

Submit Documentation Feedback

Copyright © 2018–2019, Texas Instruments Incorporated

DRV8876/74 Evaluation Module

6

Operation of the EVM

6.1

Dual Motor Operation

This mode allows for up to two motors to be controlled independently. Connect a DC motor across OUT1
and GND. If desired, connect an additional DC motor across OUT2 and GND. To reverse motor direction
of one of the motors, replace the connection from that motor to GND with a connection from that motor to
VM. This can be done with both motors if desired.

Use the following steps to operate the EVM with up to two motors with single direction speed control:

1. Connect a DC motor across OUT1 and GND. If desired, connect an additional DC motor across OUT2

and GND.

2. Adjust the potentiometer, IN1 PWM, to minimum voltage by turning the wheel counter-clockwise all the

way. This minimizes the motor speed of the motor connected across OUT1. If using a second motor,
perform this process with potentiometer IN2 PWM as well.

3. Remove the jumper from the PMODE header so the PMODE pin is Hi-Z.

4. Apply power to J1 header

5. Turn potentiometer, IN1 PWM, clockwise and the motor connected across OUT1 starts to turn.

Continue adjusting, as desired, until the maximum speed is reached. If using a second motor perform
this process with potentiometer IN2 PWM as well.

6. The direction of the motor turning can be reversed, if desired, by removing the connection from GND to

the motor and connecting the motor to VM. If this is done, the potentiometer associated with controlling
the motor will operate in reverse and thus should be turned all the way clockwise before powering on
the board and then slowly turned counter-clockwise to speed up the motor.

6.2

Single Motor Operation

This mode allows for bidirectional control of one motor. Connect a DC motor across OUT1 and OUT2.
Reversing direction os now controlled by the potentiometer. This is described in detail in

Section 6.2

.

Use the following steps to operate the EVM with a signal motor and bidirectional speed control:

1. Connect a motor across OUT1 and OUT2.

2. Use a jumper to connect the PMODE header to 3.3 V or GND to set the input mode to PWM control

mode or PH/EN mode respectively.

3. Adjust both potentiometers, IN1 PWM and IN2 PWM, according to the table of the corresponding

PMODE setting in

Section 5.1

.

4. Apply power to J1 header.

5. Control the motor direction and speed by adjusting the potentiometers according to the tables in

Section 5.1

.

Содержание DRV887 Series

Страница 1: ...for extended periods of time at an ambient temperature of 25 C DRV8874EVM and DRV8874 Q1EVM are rated for power supply voltages between 4 5 VDC and 37 VDC max The components can support peak output cu...

Страница 2: ...pyright 2018 2019 Texas Instruments Incorporated DRV8876 74 Evaluation Module 1 PH EN Control Mode 6 2 PWM Control Mode 7 3 Independent Half Bridge Control Mode 8 Trademarks MSP430 eZ FET are trademar...

Страница 3: ...ability the MSP430 MCU can be reprogrammed through the eZ FET emulation circuit found in newer MSP430 Launchpads We recommend the http www ti com tool MSP EXP430FR5969 Note that a four pin angled male...

Страница 4: ...the DRV8876 74 When nFAULT is low the Fault LED D2 will turn on The VREF potentiometer sets a reference voltage between 0 V and 3 3 V The IPROPI signal voltage will be proportional to the current out...

Страница 5: ...eed Adjustment Potentiometers 5 SLVUBG7C August 2018 Revised December 2019 Submit Documentation Feedback Copyright 2018 2019 Texas Instruments Incorporated DRV8876 74 Evaluation Module Figure 2 PMODE...

Страница 6: ...H bridge to be controlled with a speed and direction type of interface The truth table for PH EN mode is shown in Table 1 This method is best for bidirectional driving for one motor Figure 3 PMODE ju...

Страница 7: ...truth table for PWM mode is shown in Table 2 This method is best for bidirectional driving for one motor Figure 4 PMODE jumper configuration for PWM Table 2 PWM Control Mode IN1 IN2 OUT1 OUT2 DESCRIPT...

Страница 8: ...tched into independent half bridge control mode This mode allows for each half bridge to be directly controlled in order to support high side slow decay or driving two independent loads The truth tabl...

Страница 9: ...ometer IN1 PWM clockwise and the motor connected across OUT1 starts to turn Continue adjusting as desired until the maximum speed is reached If using a second motor perform this process with potentiom...

Страница 10: ...e resources are subject to change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reprod...