Texas Instruments DRV8412EVM Скачать руководство пользователя страница 4

Operation

www.ti.com

2

Operation

2.1

Quick Start List for Stand-Alone Operation

Follow these steps to use the DRV8412EVM stand-alone or when connecting it into existing circuits or
equipment. Connections to the EVM module can be made by inserting stripped wire for the power supplies
and output connections.

2.1.1

Power Supply

Two power supplies are required to power up the EVM. One is needed for system power, logic and gate
drive, while the second is for the output stage power supply. Please use enough wire gauge such that the
impedance is relatively low. The output stage supply should use at least AWG 22 wire.

Table 2. Power Supply Requirements

Description

Voltage Range

Current Requirements

Wire Size

System Power Supply

12 V

1 A

26 AWG

Output Stage Power Supply

0 – 50 V

6 A

22 AWG

2.1.2

Evaluation Module Preparation

Inputs and Outputs

1. Ensure that all external power sources are set to OFF.
2. Connect load(s) across the outputs (OUTX) or between the outputs and ground depending on the

configuration requirement.

3. Connect an external 12V power supply to the terminal block marked GVDD and GND (J2). Make sure

the wires are connected with correct polarities.

4. Connect an external regulated power supply adjustable from 0V - 50V to the terminal block marked

PVDD and GND (J5). Make sure the wires are connected with correct polarities.

Control Signals

1. Install the mode jumpers on M3, M2, and M1 depending on the mode desired. See "Mode Pin

Configurations" table for detail.

2. Set RESET_AB (S1) and RESET_CD (S2) switches to low (RESET) position.
3. Prepare the PWM signals needed to control the power stage and make sure that PWM logic is 3.3V

not 5V.

2.1.3

Power Up

The DRV8412 device doesn't require a special power up sequence, but the following sequence is
recommended for the EVM.

1. Turn on GVDD (12V) power supply.
2. Enable PWM signals.
3. Set RESET_AB (S1) and RESET_CD (S2) switches to high (NORMAL OPERATION) position.
4. Turn on the external PVDD power supply to the desired voltage gradually.
5. Adjust the duty cycle of PWM input signals to the desired value. The EVM should begin to operate

normally.

2.1.4

Fault Conditions

When device shuts down due to any fault conditions, flip RESET_AB and/or RESET_CD switches back
and forth to clear the fault and reset the device. If this doesn't work for any reason, turn 12V GVDD power
supply off and on again to clear the latch. Please inspect the board and test condition carefully to
understand the problem before next operation.

4

DRV8412EVM Motor Drive Evaluation Board

SLOU287 – January 2010

Submit Documentation Feedback

Copyright © 2010, Texas Instruments Incorporated

Содержание DRV8412EVM

Страница 1: ...B Layers and Bill of Materials 6 List of Figures 1 The TI DRV8412EVM Motor Drive Evaluation Board Top View 3 2 The TI DRV8412EVM Motor Drive Evaluation Board Bottom View 3 3 DRV8412EVM Schematic 6 4 D...

Страница 2: ...it can be operated with external PWM inputs using a MCU controller module or signal generator etc The outputs and power supplies can be connected using stripped wires by connecting them to the on boar...

Страница 3: ...VM Motor Drive Evaluation Board Top View Figure 2 The TI DRV8412EVM Motor Drive Evaluation Board Bottom View 3 SLOU287 January 2010 DRV8412EVM Motor Drive Evaluation Board Submit Documentation Feedbac...

Страница 4: ...r supply adjustable from 0V 50V to the terminal block marked PVDD and GND J5 Make sure the wires are connected with correct polarities Control Signals 1 Install the mode jumpers on M3 M2 and M1 depend...

Страница 5: ...o PWM inputs each full bridge or four half bridges with OC latching shutdown no cycle by cycle current limit 0 1 0 1 PFB Parallel full bridge with cycle by cycle current limit 0 1 1 1 FB Dual Full Bri...

Страница 6: ...14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 5 0V 500mA SOT223 DCY UA78M05CDCY VR2 3 2 1 GND VIN VOUT 3 3V 500mA SOT223 DCY 1 2 3 VR1 UA78M33CDCY GND VIN VOUT 47ufd 16V FC C11 0 1ufd 100V 0805...

Страница 7: ...erials 3 2 DRV8412EVM PCB Layers Figure 4 DRV8412EVM Top Layer Composite Figure 5 DRV8412EVM Top Layer Copper 7 SLOU287 January 2010 DRV8412EVM Motor Drive Evaluation Board Submit Documentation Feedba...

Страница 8: ...SML LXT0805YW TR 1 C3 CAP SMD0805 CERM 0 01UFD 100V Digi Key PCC1991CT Panasonic ECJ 2VB2A103K 10 X7R ROHS 5 C5 C7 C10 CAP SMD0603 CERM 0 1UFD 16V 10 Digi Key PCC1762CT Panasonic ECJ 1VB1C104K C12 C2...

Страница 9: ...Technology ROHS 1 J2 TERMINAL BLOCK 2PIN 6A 250V GRAY Digi Key ED1534 On Shore ED655 2DS ED600 2DS 7mm PITCH 16 28AWG ROHS Technology 2 J3 J4 TERMINAL BLOCK 2PIN 15A 250V Digi Key ED1627 On Shore BLU...

Страница 10: ...h statements TI products are not authorized for use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury...

Страница 11: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Texas Instruments DRV8412DDWEVM...

Отзывы: