3.2.2.3 DAC Quick-Start Page
This page is divided in to four tabs:
Basic DAC
,
Margining
,
Functions
, and
Alarms
. The following subsections
describe each tab.
3.2.2.3.1 Basic DAC Tab
The
Basic DAC
provides an interface to quickly power up, select the
reference and output span, and program the output voltage (decimal) for the DAC53701. The DAC53701 comes
in Hi-Z power-down mode by default.
Note
The basic DAC setup for power up, reference selection, and output span selection available in this tab
is common to all the tab functions.
Figure 3-7. DAC Quick-Start Page: Basic DAC Tab
The EEPROM
PROGRAM
button is used to write the latest register settings to the EEPROM.
The
RELOAD
button is used to retrieve the settings stored in the EEPROM.
The GPI pin programming has not been provided in this version of the software, although the EVM hardware has
options for providing signals to DAC53701 through header J2
Detailed Description
SLAU841 – OCTOBER 2020
DAC53701EVM
17
Copyright © 2020 Texas Instruments Incorporated