CC112X/CC1175
SWRU295C
Page 88 of 108
TOC_CFG - Timing Offset Correction Configuration
Bit no.
Name
Reset
R/W Description
7:6
TOC_LIMIT
0x00
R/W Timing Offset Correction Limit.
TOC_LIMIT
specifies maximum data rate offset
the receiver are able to handle.
TOC_LIMIT != 00b
requires 2 - 4 bytes
preamble for data rate offset loop to settle
00
< 2000 ppm
01
< 20000 ppm
10
Reserved
11
< 120000 ppm (
must be set)
5:3
TOC_PRE_SYNC_BLOCKLEN
0x01
R/W When
TOC_LIMIT = 0
the receiver uses a block based time offset error
calculation algorithm where the block length is configurable through register
TOC_CFG.
Before a sync word is found (
is asserted) the
TOC_PRE_SYNC_BLOCKLEN
sets the actual block length used for the time offset
algorithm
000
8 symbols integration window
001
16 symbols integration window
010
32 symbols integration window
011
64 symbols integration window
100
128 symbols integration window
101
256 symbols integration window
110
Reserved
111
Reserved
If
TOC_LIMIT != 0
: Symbol by Symbol Timing Error Proportional Scale Factor
X00
Proportional scale factor = 8/16
X01
Proportional scale factor = 6/16
X10
Proportional scale factor = 2/16
X11
Proportional scale factor = 1/16
1XX
Proportional scale factor = 1/16 after sync found
2:0
TOC_POST_SYNC_BLOCKLEN
0x03
R/W When
TOC_LIMIT = 0
the receiver uses a block based time offset error
calculation algorithm where the block length is configurable through register
TOC_CFG
. After a sync word is found (
is asserted) the
TOC_POST_SYNC_BLOCKLEN
sets the actual block length used for the time
offset algorithm
000
8 symbols integration window
001
16 symbols integration window
010
32 symbols integration window
011
64 symbols integration window
100
128 symbols integration window
101
256 symbols integration window
110
Reserved
111
Reserved
If
TOC_LIMIT != 0
: Symbol by Symbol Timing Error Proportional Scale Factor
x00
Integral scale factor = 8/32
x01
Integral scale factor = 6/32
x10
Integral scale factor = 2/32
x11
Integral Scale Factor = 1/32
1xx
Integral Scale Factor = 1/32 after sync found
MARC_SPARE - MARC Spare
Bit no.
Name
Reset
R/W Description
7:4
MARC_SPARE_NOT_USED
0x00
R
3:0
MARC_SPARE_RESERVED3_0
0x00
R/W For test purposes only, use values from SmartRF Studio