CC112X/CC1175
SWRU295C
Page 74 of 108
MDMCFG1 - General Modem Parameter Configuration
Bit no. Name
Reset
R/W Description
7
CARRIER_SENSE_GATE
0x00
R/W When
CARRIER_SENSE_GATE
is 1, the demodulator will not start to look for a sync word
before
is asserted
0
Search for sync word regardless of CS
1
Do not start sync search before
is asserted
6
FIFO_EN
0x01
R/W FIFO Enable. Specifies if data to/from modem will be passed through the FIFOs or
directly to the serial pin
0
Data in/out through the serial pin(s) (the FIFOs are bypassed)
1
Data in/out through the FIFOs
5
MANCHESTER_EN
0x00
R/W Manchester Enable. Manchester coding is only applicable to payload data including
optional CRC. Manchester coding is not supported for 4-(G)FSK
0
NRZ
1
Manchester encoding/decoding
4
INVERT_DATA_EN
0x00
R/W Invert Data Enable. Invert payload data stream in RX and TX (only applicable to payload
data including optional CRC)
0
Invert data disabled
1
Invert data enabled
3
COLLISION_DETECT_EN
0x00
R/W Collision Detect Enable. After a sync word is detected, the receiver will always receive a
packet. If collision detection is enabled, the receiver will continue to search for sync. If a
new sync word is found during packet reception, a collision is detected and the
flag will be asserted
0
Collision detect disabled
1
collision detect enabled
2:1
DVGA_GAIN
0x03
R/W Fixed DVGA gain configuration
00
0 dB DVGA
01
3 dB DVGA
10
6 dB DVGA
11
9 dB DVGA
0
SINGLE_ADC_EN
0x00
R/W Configure the number of active receive channels. If this bit is set the power consumption
will be reduced but the sensitivity level will be reduced by ~3 dB. Image rejection will not
work
0
IQ-channels
1
Only I-channel