Cell Voltage Monitor Tab (ADC Config)
11
SLUUBQ2C – July 2017 – Revised April 2019
Copyright © 2017–2019, Texas Instruments Incorporated
Getting Started with the BQ79606A-Q1 GUI
read (
a. Click “read” to update cell values.
b. Values will be read in as a voltage, or alternatively as a two bye Hex value
c. VCELLX_F contains cell values after the ADC output filter
d. VCELLX contains corrected cell values before the ADC output filter
e. To continue reading cell voltages, click “START ADC MEASUREMENT” and read the registers
again to update cell voltages.
Figure 14. Updating Cell Voltage Registers
3.2
Continuous ADC Configuration and Readings Configuration
1. Configure CELL channels and the ADC in available fields
a. Select ADC Delay, Decimation Ratio, ADC Frequency, Cell Conversion Interval, and LP Corner
Frequency
b. Select desired cells to sample under CELL SELECTION
c. Check “Continuous Cell Conversions Enable” (Labeled 1 in
d. Click “Write” (Labeled 2 in
)
e. Click” START ADC MEASUREMENT” (Labeled 3 in
) to begin sampling cells
f.
Click “Read” to update voltage registers.
g. Repeat step f as needed to update voltage registers