![Texas Instruments bq51020EVM Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/texas-instruments/bq51020evm/bq51020evm_user-manual_1097082012.webp)
Test Results
7.2
Load Step
The procedure for load step is as follows:
•
Set up the test bench as described in
•
Power WPC TX (bq500210) with 19 V.
•
Provide a load step from no-load (high impedance) to 1000 mA (if using current source load).
•
Monitor on side RX: load current, rectifier voltage, and output voltage as shown in
Figure 3. Load Step
7.3
Start Up
The procedure for start-up test with load:
•
Set up the test bench as described in
•
Power the WPC TX
•
Apply 10
Ω
across J3 and J4, put the receiver EVM on the transmitter coil, and align them correctly
•
Monitor the RECT pin, I
OUT
, and output voltage, as shown in
.
12
bq51020EVM (5-W WPC) Integrated Wireless Receiver Power Supply
SLUUB03 – April 2014
Copyright © 2014, Texas Instruments Incorporated