Operation
Figure 10. SBS Data Screen
This screen shows the SBS data set along with additional ManufacturersAccess() command information,
such as individual cell measurements. Additional Flag and Static data can be viewed by selecting the
appropriate tab at the bottom of the SBS screen.
Data such as SBS.ManufacturerName( ) is static and does not change. This data is viewed separately
using the Static Data tab at the bottom of the screen.
Dragging the splitter bar (the line that separates the Flags/Static data from SBS values) changes the
height of the Flags/Status Bits display. Selecting View then Auto Arrange returns the splitter bar to its
original location.
8.2
Setting Programmable bq30z554 Options
The bq30z554 data flash comes configured per the default settings detailed in the bq30z554 SBS 1.1-
Compliant Gas Gauge With Impedance Track™ Datasheet (
A). Ensure that the settings are
correctly changed to match the pack and application for the bq30z554 solution being evaluated.
IMPORTANT: To get the best performance, it is essential to correctly set these options.
Use the Data Flash screen to configure the settings.
13
SLUUA36 – November 2012
bq30z554EVM SBS 1.1 Impedance Track™ Enabled Battery Management
Solution EVM
Copyright © 2012, Texas Instruments Incorporated