Texas Instruments BQ27620 Скачать руководство пользователя страница 9

EV2300 or EV2400

USB

H

D

Q

I2

C

S

M

B

LOAD

CHARGER

Battery

Pack

T

www.ti.com

Operation

Figure 6. bq27620 Circuit Module Connection to Pack and System Load/Charger

7.2

PC Interface Connection

The following steps configure the hardware for interface to the PC.

1. Connect the bq27620-based EVM to the EV2300 using wire leads as shown in

Table 4

.

2. Connect the PC USB cable to the EV2300 and the PC USB port.

Table 4. Circuit Module to EV2300/EV2400 Connections

bq27620EVM

EV2300

SDA

SDA

SCL

SCL

VSS

GND

The bq27620EVM is now set up for operation.

8

Operation

This section details the operation of the bq27620 EVSW software.

8.1

Starting the Program

Run bq27620 EVSW from the Start | Programs | Texas Instruments | bq Evaluation Software menu
sequence. The DataRAM screen (

Figure 7

) appears. Data begins to appear once the

<

Refresh

>

(single

time scan) button is clicked, or when the

<

Keep Scanning

>

check box is checked. To disable the scan

feature, deselect

<

Keep Scanning

>

.

The continuous scanning period can be set with the | Options | and | Set Scan Interval | menu selections.
The range for this interval is 0 ms to 65,535 ms. Only items that are selected for scanning are scanned
within this period.

9

SLUU655

October 2011

bq27620 EVM: Single-Cell Impedance Track Technology

Submit Documentation Feedback

Copyright

©

2011, Texas Instruments Incorporated

Содержание BQ27620

Страница 1: ...tures 2 1 1 Kit Contents 2 1 2 Ordering Information 2 2 bq27620 Based Circuit Module 3 2 1 Circuit Module Connections 3 2 2 Pin Description 3 3 bq27620 Circuit Module Schematic 3 3 1 Schematic 3 4 Cir...

Страница 2: ...sonal computer PC software and interface board for easy evaluation Software that allows data logging for system analysis Ability to upgrade to the latest firmware version by flash reprogramming 1 1 Ki...

Страница 3: ...CK Pack positive terminal PACK Pack negative terminal SDA I2C communication data line SCL I2C communication clock line VSS Signal return for communication line shared with charger and ground CHG LOAD...

Страница 4: ...terial www ti com Figure 1 bq27620EVM Layout Silk Screen Figure 2 bq27620EVM Layout Top Assembly 4 bq27620 EVM Single Cell Impedance Track Technology SLUU655 October 2011 Submit Documentation Feedback...

Страница 5: ...d Bill of Material Figure 3 bq27620EVM Layout Top Layer Figure 4 bq27620EVM Layout Bottom Layer 5 SLUU655 October 2011 bq27620 EVM Single Cell Impedance Track Technology Submit Documentation Feedback...

Страница 6: ...le 0 400 x 0 500 22 05 3041 Molex 2 J4 J9 PEC36SAAN Header Male 3 pin 100mil spacing 0 100 inch x 3 PEC36SAAN Sullins 1 R1 1 8M Resistor Chip 1 16 W 5 402 Std Std 2 R11 R12 10k Resistor Chip 1 16 W 5...

Страница 7: ...ysical Layout and Bill of Material 4 3 Schematic Figure 5 bq27620EVM Schematic 7 SLUU655 October 2011 bq27620 EVM Single Cell Impedance Track Technology Submit Documentation Feedback Copyright 2011 Te...

Страница 8: ...ts contents into a temporary directory 3 Open the software file that was downloaded from the TI Web site 4 Follow the instructions on screen until completing the software installation 5 Before startin...

Страница 9: ...tion details the operation of the bq27620 EVSW software 8 1 Starting the Program Run bq27620 EVSW from the Start Programs Texas Instruments bq Evaluation Software menu sequence The DataRAM screen Figu...

Страница 10: ...be viewed at the bottom of the DataRAM screen Dragging the splitter bar line that separates the Flags Status data from Data Ram register values changes the height of the Flags Status Data display Sel...

Страница 11: ...and written to the bq27620 using the Write All button The module calibration data is also held in the bq27620 data flash The bq27620 allows for an automatic data flash export function similar to the D...

Страница 12: ...asured values for the types selected 3 Press the button to calibrate 9 2 Voltage Calibration 1 Measure the voltage across Pack and Pack 2 Type the voltage value in mV into Enter Actual Voltage 3 Press...

Страница 13: ...y of any of the following TI documents call the Texas Instruments Literature Response Center at 800 477 8924 or the Product Information Center PIC at 972 644 5580 When ordering identify this document...

Страница 14: ...product This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application engi...

Страница 15: ...or use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury or death unless officers of the parties have...

Отзывы: