bq27441 Data Memory Parameter Descriptions
6.4.1.2.3 DOD at EOC Delta Temperature
Subclass
Subclass
Offset
Type
Name
Value
Unit
ID
Min
Max
Default
Charge
36
7
I2
DODatEOC Delta T
0
1000
50
0.1°C
Termination
During relaxation and charge start,
RemainingCapacity()
=
FullChargeCapacity()
– Qstart. But with
temperature decreases, Qstart can become much smaller than old
FullChargeCapacity()
resulting in an
over-estimation of
RemainingCapacity()
. To improve accuracy, gauging predictions are updated when the
temperature has changed by at least
DODatEOC Delta T
since the last simulation.
6.4.1.3
Data Subclass
6.4.1.3.1 Initial Standby Current
Subclass
Subclass
Offset
Type
Name
Value
Unit
ID
Min
Max
Default
Data
48
2
I1
Initial Standby
–128
0
–3
mA
This is the initial value that is reported in
StandbyCurrent()
. The
StandbyCurrent()
value is updated every
1 second when the measured current meets the following criteria:
|Current| >
Deadband
and Current
≤
2 ×
Initial Standby.
NOTE:
Current is negative during discharge.
This value depends on the system. The initial standby current is the current load drawn by the system
when in low-power mode.
6.4.1.3.2 Initial Maximum Load Current
Subclass
Subclass
Offset
Type
Name
Value
Unit
ID
Min
Max
Default
Data
48
3
I2
Initial MaxLoad
–32768
0
–200
mA
This is the initial value that is reported in
MaxLoadCurrent()
. The
MaxLoadCurrent()
is updated to the new
current when Current >
Initial MaxLoad
.
MaxLoadCurrent()
is reduced to the average of the previous
value and
Initial MaxLoad
whenever the battery is charged to full after a previous discharge to an SOC
less than 50%. This prevents the reported value from maintaining an unusually high value. Default value
depends on the system.
34