www.ti.com
Test Summary
2.4.3
CHARGE CURRENT AND AC CURRENT REGULATION (DPM)
1. Install JP9 (Disable the charging).
2. Connect the Load 2 in series with a current meter (multimeter) to J6 (BAT, GND). Make sure a voltage
meter is connected across J6 (BAT, GND). Turn on the Load 2. Set the output voltage to 10.5V.
3. Connect the output of the Load 1 in series with a current meter (multimeter) to J6 (SYS, GND). Make
sure a voltage meter is connected across J6 (SYS, GND). Turn on the power of the Load 1. Set the
load current to 4A ± 50mA but disable the output. The setup is now like
for HPA207-001, -004
or -005 and like
for HPA207-002, -003, -006, or -007. Make sure Ibat = 0A ± 10mA and Isys =
0A ± 10mA.
Figure 3. Test Setup for HPA207-001, -004, or -005
Figure 4. Test Setup for HPA207-002, -003, -006, or -007
4. Uninstall JP9 (Enable the charging).
Observe
→
D3 (CHG EN) on
5. Measure
→
Ibat = 3000mA ± 200mA
Measure
→
V(TP(IOUT)):= 300mV ± 100mV (For HPA207-001, 002, -003, -005, -006, or -007)
Measure
→
V(TP(IOUT)):= 600mV ± 100mV (For HPA207-004 only)
6. Enable the output of the Load 1.
Observe
→
D5 (DPMDET) on (For HPA207-001, -004, or -005 only)
Measure
→
Isys = 4000mA ± 200mA, Ibat = 1000mA ± 500mA, Iin = 4500mA ± 400mA
7. Turn off the Load 1.
Measure
→
Isys = 0 ± 100mA, Ibat = 3000mA ± 200mA
7
SLUU283D – May 2007 – Revised March 2010
bq24750/50A/51/51A/51B/52/53 EVM (HPA207) For Multi —Cell Synchronous
Notebook Charger and System Power Selector
Copyright © 2007–2010, Texas Instruments Incorporated