J4
To Computer
USB Port
USB Interface
Adapter
I/O
USB
10-pin
Ribbon Cable
‘To EVM’
T
exas Instruments
©
2006
Test Summary
2.2
Equipment Setup
1. Set PS#1 for 5-V DC, 1-A current limit and then turn off the supply.
2. Connect the output of PS#1 in series with a current meter (multimeter) to J1 (V
BUS
and GND).
3. Connect a voltage meter across J1 (V
BUS
) and J1 (GND).
4. Turn on the Load, set to constant voltage mode and output to 2.5 V. Turn off (disable) Load. Connect
Load in series with a current meter (multimeter), ground side, to J2 (BAT+ and GND) as shown in
5. Connect a voltage meter across J2 (BAT+ and GND).
6. Connect the HPA172 USB interface adapter to the computer with a USB mini-cable and to J3 with the
10-pin ribbon cable. The connections are shown in
Figure 1. Connections of the HPA172 Kit
7. Install shunts as shown in
.
Figure 2. Original Test Setup for PWR021 (bq2419xEVM)
5
SLUUA14A – October 2012 – Revised April 2013
bq24190/2/2i/3/6 and bq24292i EVM (PWR021) User’s Guide