ADS7142-Q1 GUI Functional Modes
16
SBAU321A – November 2018 – Revised August 2019
Copyright © 2018–2019, Texas Instruments Incorporated
BOOSTXL-ADS7142-Q1 BoosterPack™ Plug-In Module
shows the GUI after an Alert condition is encountered. In this example, Channel 0 has reached
the
High Threshold
. This is indicated by the
High Threshold
indicator on the right side of the
corresponding graph. Since the device is configured for
Pre Alert Mode
operation with both channels
enabled, the conditions prior to reaching the
Alert
condition are displayed. The
Alert
condition must be
cleared, by clicking on the
Threshold
indicator before the next sequence is run to ensure normal operation
of the device.
Figure 15. Operation After Alert Condition