Texas Instruments AMC1204EVM Скачать руководство пользователя страница 4

Power-Supplies

www.ti.com

4

Power-Supplies

J2 provides access to the +5 VA for the V

DD

2 supply. All power to the board should be sourced from a

well-regulated, linear supply that has current limiting capabilities. Power is to be applied through J2.

Table 1

describes the pinout for J2.

Table 1. J2: Power Supply and Digital Outputs

Signal

Pin Number

Signal

Ground

1

2

Not used

4.5 to 5.5 V

DD

2 supply

3

4

Not used

Ground

5

6

Optional CLKIN output

CLKIN default

7

8

DATA default

Optional DATA output

9

For standalone operation, power sources can also be applied via a mating connector to J2, and the digital
output data stream can be wired directly to an FPGA or other digital filter module for further processing.
Refer to

Figure 2

or the schematic appended to the end of this document for additional details.

5

EVM Set-up and Operation

This section describes the general operation of the AMC1204EVM.

5.1

Isolated Power and Analog Inputs: J1 and J4

The isolated power input to the AMC1204EVM printed circuit board (PCB) can be applied directly to J1,
pins 1 and 2.

Table 2

lists the details of J1.

Table 2. J1: Isolated Power

Pin Number

Signal

Description

J1.1

ISOGND

Connection to the AMC1204 GND1 pin

J1.2

5 V

ISO

Connection to the AMC1204 VDD1 terminal

The analog input to the AMC1204EVM PCB can be applied directly to J4 pins 1 and 2.

Table 3

lists the

details of J4.

CAUTION

Carefully review the

AMC1204 product data sheet

for the limitations of the

analog input range, and ensure that the appropriate analog/digital voltages are
applied before connecting any analog input to the EVM.

Table 3. J4: Analog Inputs

Pin Number

Signal

Description

J4.1

CHA+

Noninverting analog input to the AMC1204

J4.2

CHA–

Inverting input to the AMC1204

4

AMC1204EVM

SBAU178 – August 2010

Copyright © 2010, Texas Instruments Incorporated

Содержание AMC1204EVM

Страница 1: ...ww ti com Device Literature Number AMC1204 SBAS512 AMC1210 SBAS372 Contents 1 AMC1204EVM Overview 2 1 1 Features 2 1 2 Introduction 2 2 Analog Interface 2 2 1 Analog Inputs 2 3 Digital Interface 3 4 P...

Страница 2: ...n be used to achieve 16 bit analog to digital A D conversion with no missing codes For use in high resolution measurement applications an effective accuracy of 14 bits can be obtained with a digital f...

Страница 3: ...9 pin female D type connector Both the analog and digital power for the AMC1204 as well as the modulator data and clock outputs from the device under test are routed to J2 as Figure 2 illustrates Fig...

Страница 4: ...ils 5 EVM Set up and Operation This section describes the general operation of the AMC1204EVM 5 1 Isolated Power and Analog Inputs J1 and J4 The isolated power input to the AMC1204EVM printed circuit...

Страница 5: ...e maximum input level of 320mV the 1s density of the modulator output approaches 92 Likewise when the input voltage approaches the lower limit of 320 mV the 1s density is approximately 8 6 BOM Schemat...

Страница 6: ...G1H331J C4 C5 Capacitor ceramic 10 pF 50 V C0G 0603 TDK C1608C0G1H100D D1 Not installed J1 J4 Terminal block 3 5 mm 2 pos PCB On Shore ED555 2DS J2 Connector DB 9 female solder cup tin Norcomp 172 009...

Страница 7: ...Hendrick Tom Hendrick C Userdata EVMS AMC1204 AMC1204 ddb Documents SCH AMC1204 A 1 1 AMC1204EVM DOCUMENT CONTROL NO TBD 1 6 2 7 3 8 4 9 5 J2 RS232 VDD2 VDD2 VDD2 C1 0 1uF C2 4 7uF 1 2 3 4 J3 HEADER 4...

Страница 8: ...product This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application eng...

Страница 9: ...h statements TI products are not authorized for use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury...