Figure 3-29. CAN Interface
3.4.15 Interrupt
The GP EVM supports the following timer and interrupt options.
Three push button switches are available to provide reset for MCU_PORz and MCU_RESETz & RESET_REQz.
One push button switch is available for GPIO interrupt which is connected to both main domain and MCU
domain GPIO pin.
Warm reset can also be applied through Test automation header or manual reset switches SW4(SoC) and
SW6(MCU).
Power on reset input can be applied though switch SW7.
3.4.16 ADC Interface
A 20-pin connector J3 of part number TSW-110-07-S-D for connecting ADC signals of AM64x SoC. The
connector includes ADC0_AIN0-7, VDDA_ADC connections and ground connections.
Table 3-26. ADC Connector (J3) Pin-out
Pin No.
Signal
Pin No.
Signal
1
DGND
11
ADC0_AIN7
2
NC
12
DGND
3
ADC0_AIN6
13
DGND
4
VDDA_ADC
14
ADC0_AIN1
5
DGND
15
ADC0_AIN0
6
ADC0_AIN2
16
DGND
7
ADC0_AIN5
17
VDDA_ADC
8
DGND
18
ADC0_AIN3
9
DGND
19
NC
10
ADC0_AIN4
20
DGND
System Description
48
AM64x GP EVM User's Guide
SPRUIX0B – FEBRUARY 2021 – REVISED MARCH 2021