![Texas Instruments AM1808 Скачать руководство пользователя страница 1206](http://html.mh-extra.com/html/texas-instruments/am1808/am1808_technical-reference-manual_10945581206.webp)
D(R/X)
FS(R/X)
CLK(R/X)
Element 3
Phase 2
Element 2
Phase 2
Element 1
Phase 2
Element 2
Phase 1
Element 1
Phase 1
Á
Á
Á
Á
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Á
Á
Á
Á
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Á
Á
Á
Á
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Á
Á
Á
Á
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Á
Á
Á
Á
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Á
Á
Á
Á
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Á
Á
Á
Á
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Á
Á
Á
Á
Á
Á
Á
Á
ÁÁ
ÁÁ
ÁÁ
ÁÁ
Architecture
1206
SPRUH82C – April 2013 – Revised September 2016
Copyright © 2013–2016, Texas Instruments Incorporated
Multichannel Buffered Serial Port (McBSP)
Figure 25-10. Dual-Phase Frame Example
Table 25-7. RCR/XCR Fields Controlling Elements per Frame and
Bits per Element
Serial Port
Frame
Phase
RCR/XCR Field Control
Elements per Frame
Bits per Element
Receive
1
RFRLEN1
RWDLEN1
Receive
2
RFRLEN2
RWDLEN2
Transmit
1
XFRLEN1
XWDLEN1
Transmit
2
XFRLEN2
XWDLEN2
25.2.5.5.2 Frame Length: RFRLEN1/2 and XFRLEN1/2
Frame length specifies the maximum number of serial elements or logical time slots or channels that are
available for transfer per frame synchronization signal. In multichannel selection mode, the frame length
value is independent of, and perhaps different from, the actual number of channels that the device is
programmed to receive or transmit per frame via the MCR, RCERE
n
, and XCERE
n
registers. See
for details on multichannel selection mode operation. The 7-bit (R/X)FRLEN1/2 bits in
(R/X)CR support up to 128 elements per phase in a frame, as shown in
. (R/X)PHASE = 0
selects a single-phase data frame, and (R/X)PHASE = 1 selects a dual-phase frame for the data stream.
For a single-phase frame, the value of (R/X)FRLEN2 does not matter. Program the frame length fields
with (
w
minus 1), where
w
represents the number of elements per frame. For
, (R/X)FRLEN1
= 1 or 000 0001b and (R/X)FRLEN2 = 2 or 000 0010b.
Table 25-8. Receive/Transmit Frame Length Configuration
(R/X)PHASE
(R/X)FRLEN1
(R/X)FRLEN2
Frame Length
0
0
≤
n
≤
127
x
Single-phase frame; (n + 1) elements per frame
1
0
≤
n
≤
127
0
≤
m
≤
127
Dual-phase frame; (n + 1) plus (m + 1) elements per frame
25.2.5.5.3 Element Length: RWDLEN1/2 and XWDLEN1/2
The (R/X)WDLEN1/2 fields in the receive/transmit control register (RCR and XCR) determine the element
length in bits per element for the receiver and the transmitter for each phase of the frame, as indicated in
.
shows how the value of these fields selects particular element lengths in bits. For
the example in
, (R/X)WDLEN1 = 001b and (R/X)WDLEN2 = 000b. If (R/X)PHASE = 0,
indicating a single-phase frame, then (R/X)WDLEN2 is not used by the McBSP and its value does not
matter.