VCC_S
VCC_1
VCC_2
-
+
-
+
VS
VS_O1
IN1-
IN1+
EN
OUT1
11
1
3
2
12
13
-
+
VS_O2
IN2+
IN2-
EN
OUT2
4
5
10
9
+
NC
NC
8
7
GND
Thermal
Shutdown
SH_DN/OTF
EN
GND
15
6
A1
A2
14
GND
(TAB)
U1 ALM2402F-Q1
C4 100nF
C5
100nF
C10
100nF
10uF
C18
100nF
C19
VCC_1
VCC_S
VCC_2
10uF
C22
100nF
C23
10uF
C25
100nF
C26
GND
GND
GND
D1
1
2
3
4
5
6
J7
GND
1 2 3
J5
1
2
3
J10
1
2
3
J8
VCC_S
VCC_S
Power Supply
connector
Power-Supply Connections
5
SBOU227 – September 2019
Copyright © 2019, Texas Instruments Incorporated
ALM2402F-Q1 Evaluation Module
4
Power-Supply Connections
The power-supply connections for the ALM2402FQ1EVM are provided through connector J7 at the top of
the EVM.
summarizes the pin definition for supply connector J7, and the allowed voltage range for
each supply connection.
Table 2. ALM2402FQ1EVM Supply-Range Specifications
Pin Number
Supply Connection
Voltage Range
J7.1
Input stage supply (VCC)
4.5 V to 16 V
J7.2, J7.4, J7.6
Ground
0 V
J7.3
Op amp 1 output supply (VCC_1)
3 V to 16 V
J7.5
Op amp 2 output supply (VCC_2)
3 V to 16 V
By default, the ALM2402FQ1 is configured to use a single supply connected through J7.1 (VCC) and J7.2
(GND) with jumpers J8 and J10 set to shunt pins 1-2. Alternatively, the EVM can be configured to use
three independent power-supply connections: input stage supply (VCC), op amp 1 output supply (VCC_1),
and op amp 2 output supply (VCC_2). Setting jumpers J8 and J10 to shunt pins 2-3 allows the use of
independent voltage supplies as indicated in
Figure 3. ALM2402FQ1EVM Configured With Independent Input-Stage and Output-Stage Supplies