background image

Optional Configurations

www.ti.com

2.6

ADS42xx Performance Results

Figure 5

shows the performance result at 250 MSPS clock frequency and with a 170 MHz input tone.

Figure 5. FFT Plot: 250 MHz Clock, 170 MHz Input

3

Optional Configurations

3.1

THS4509 Input Op-Amp Configuration

The default analog input configuration is transformer coupling through T1 and T2 for channel A, and T3
and T4 for channel B. The optional configuration for analog input is through an Operational-Amplifier
THS4509. The changes required to modify the transformer coupled input to the OPA-driven input are
shown in

Table 3

.

Table 3. Jumper Setting for Transformer-Coupled or OPA-Driven Input

Jumpers or 0

Ω

Transformer-Coupled Input (default)

OPA-Driven Input

R119

Install

Do not install

R123

Install

Do not install

R120

Do not install

install

R129

Do not install

install

R143

Install

Do not install

R141

Install

Do not install

R131

Do not install

Install

R132

Do not install

Install

R93

Install

Do not install

R94

Install

Do not install

R95

Do not install

Install

R96

Do not install

Install

R97

Install

Do not install

R98

Install

Do not install

R99

Do not install

Install

R114

Do not install

Install

SJP3

Shunt 2 3, default

Shunt 1 2

SJP4

Shunt 2 3, default

Shunt 1 2

8

ADS42xx EVM

SLAU333 – March 2011

Submit Documentation Feedback

© 2011, Texas Instruments Incorporated

Содержание ADS42 EVM Series

Страница 1: ...ults 8 3 Optional Configurations 8 3 1 THS4509 Input Op Amp Configuration 8 3 2 On Board CDC72010 Clock 9 3 3 Parallel CMOS Output 9 List of Figures 1 ADS58C28_ADS42xx_GUI Front Panel Top Level 3 2 AD...

Страница 2: ...as two register tabs Top Level and Advanced The Top Level tab provides an interface to the most used registers The Advanced tab includes less used registers and provides an option to manually input ad...

Страница 3: ...GUI to bring the advanced panel to the front On this panel user can write address and data of any register into the address data boxes as shown in Figure 2 45 is address and 4 is data Press Enter on t...

Страница 4: ...y updated o Select Load Regs button o Double click on the desired register file o Click on Send All to ensure all of the values are loaded properly 1 2 4 Miscellaneous Settings Device Selection Select...

Страница 5: ...Short 1 2 DC supply JP17 Short 2 3 DC supply LDO JP19 Short 2 3 DC supply LDO JP28 Short 2 3 DC supply LDO JP29 Short 2 3 DC supply LDO JP26 Open DC supply for ext buffer JP27 Open DC supply for ext...

Страница 6: ...the TSW1200 set up and operation This document assumes the TSW1200 software is installed and functioning properly The front panel of the TSW1200 is shown in Figure 4 The following configuration needs...

Страница 7: ...erator for this input to ensure proper device evaluation Connect input signal through an appropriate BPF at either J6 or J3 Channel A or B i e 170MHz Adjust frequency of generator to match the coheren...

Страница 8: ...input are shown in Table 3 Table 3 Jumper Setting for Transformer Coupled or OPA Driven Input Jumpers or 0 Transformer Coupled Input default OPA Driven Input R119 Install Do not install R123 Install D...

Страница 9: ...ault configuration see CDCE72010 data sheet SCAS858 for details about device default configuration With a 10MHz primary reference at J19 and a 983 04 MHz VCXO on board the CDC outputs a LVCMOS clock a...

Страница 10: ...ct This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application engineer...

Страница 11: ...orized for use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury or death unless officers of the parti...

Отзывы: