5.2.2.5 Capture Configuration Settings
A slide-out menu is viewable on the right side of the
Chart
window. By clicking the slide-out for
Show Capture
Settings
, various configurations display and are selectable (as shown in
in the green box). The
drop-down menu
Capture Settings
are:
•
Select data rate
for the data output conversion rate
•
Select MUX channels
by choosing the desired input channels to be converted
•
Select FSR
for choosing the voltage input measurement range
Figure 5-20. Capture Settings
5.2.3 Configuration
The
Register Map
window (
) contains information about the configuration and the last conversion
data from the ADS1x15. The
Conversion
register contains the value of the last 16-bit conversion result read from
the ADS1115. For the ADS1015, the conversion data are 12-bit left-justified in the 16-bit register.
Because the ADS1x15 is a programmable device, the
Config, LoThresh and HiThresh
registers are
programmable and 16 bits in length.
A number of control buttons and drop-down menus exist to configure the
Register Map
read and write operations
when data are written and read from the ADS1x15.
Question mark icons (?) appear throughout the
Register Map
window. Clicking these icons opens details
pertaining to the items in the locations where they appear.
ADS1x15V2EVM-PDK GUI
SBAU362 – MARCH 2021
ADS1x15V2EVM-PDK User's Guide
25
Copyright © 2021 Texas Instruments Incorporated