Texas Instruments ADC16DX370EVM Скачать руководство пользователя страница 21

FCC Interference Statement for Class B EVM devices

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

3.2

Canada

3.2.1

For EVMs issued with an Industry Canada Certificate of Conformance to RSS-210

Concerning EVMs Including Radio Transmitters:

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.

Concernant les EVMs avec appareils radio:

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

Concerning EVMs Including Detachable Antennas:

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types
listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated.
Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited
for use with this device.

Concernant les EVMs avec antennes détachables

Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et
d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le
présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le
manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne
non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de
l'émetteur

3.3

Japan

3.3.1

Notice for EVMs delivered in Japan:

Please see

http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page

日本国内に

輸入される評価用キット、ボードについては、次のところをご覧ください。

http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page

3.3.2

Notice for Users of EVMs Considered “Radio Frequency Products” in Japan:

EVMs entering Japan are NOT certified by

TI as conforming to Technical Regulations of Radio Law of Japan.

If User uses EVMs in Japan, User is required by Radio Law of Japan to follow the instructions below with respect to EVMs:

1.

Use EVMs in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal
Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for
Enforcement of Radio Law of Japan,

2.

Use EVMs only after User obtains the license of Test Radio Station as provided in Radio Law of Japan with respect to
EVMs, or

3.

Use of EVMs only after User obtains the Technical Regulations Conformity Certification as provided in Radio Law of Japan
with respect to EVMs. Also, do not transfer EVMs, unless User gives the same notice above to the transferee. Please note
that if User does not follow the instructions above, User will be subject to penalties of Radio Law of Japan.

SPACER

SPACER

SPACER

SPACER

SPACER

Содержание ADC16DX370EVM

Страница 1: ...ADC16DX370EVM User s Guide Literature Number SLAU529A February 2014 Revised December 2014 ...

Страница 2: ...nk CPU_RESET and Verify TSW14J56EVM Status LEDs 9 3 13 Capture Data Using the HSDP Software 10 3 14 Re Verify TSW14J56EVM Status LEDs 11 4 Device Configuration 12 4 1 Supported JESD204B Device Features 12 4 2 Using the Device Configuration GUI 12 4 3 Tab Organization 14 4 4 Low Level Control 14 5 Evaluation Troubleshooting 16 6 References 16 Appendix A 17 A 1 TSW14J56EVM LED Bank and Switch Config...

Страница 3: ...Ds on the TSW14J56EVM During Typical Operation 9 2 Default State of LEDs on the TSW14J56EVM during Typical Operation 11 3 Supported and Non Supported Features of the JESD204B Device 12 4 Low Level Controls 14 5 Troubleshooting 16 6 Meaning of LEDs on the TSW14J56EVM 17 7 Required State of Switches on the TSW14J56EVM 17 3 SLAU529A February 2014 Revised December 2014 List of Figures Submit Documenta...

Страница 4: ...C sampling clock Transformer coupled clock input network to test the ADC performance with a very low noise clock source High speed serial data output over a standard FMC interface connector Device register programming via USB connector and FTDI USB to SPI bus translator The digital data from the ADC16DX370EVM board can be quickly and easily captured with the TSW14J56EVM data capture board The TSW1...

Страница 5: ...ing range of the ADC device Serial data rates and corresponding sampling rates of 7 4 Gb s 370 MSPS down to 1 6 Gb s 80 MSPS are supported For the rest of this document the ADC16DX370EVM evaluation board is referred to as EVM and the ADC16DX370 device is referred to as ADC device 5 SLAU529A February 2014 Revised December 2014 ADC16DX370EVM User s Guide Submit Documentation Feedback Copyright 2014 ...

Страница 6: ... and mini USB cable High Speed Data Converter Pro software PC computer running Windows XP 7 or 8 Two low noise signal generators TI recommends the following generators RF generator 17 dBm 40 dBc harmonics 500 fs jitter 20 kHz to 20 MHz 10 MHz to 2 GHz frequency range HP HP8644B Rohde Schwarz SMA100A Bandpass filter for clock input 370MHz or desired frequency The following filters are recommended B...

Страница 7: ...ware Download the most recent version of the HSDP software from www ti com tool dataconverterpro sw Follow the installation instructions to install the software 3 2 Install the Configuration GUI Software 1 Download the Configuration GUI software from the EVM product page at www ti com 2 Extract files from the zip file 3 Run setup exe and follow the instructions 3 3 Connect the EVM and TSW14J56EVM ...

Страница 8: ... a low noise signal generator TI recommends a Trilithic tunable bandpass filter to filter the signal from the generator Configure the signal generator for 70 MHz 0 dBm 3 It is important to frequency lock the input signal generator to the clock signal generator using the 10 MHz reference This is required to achieve coherent sampling of the input signal and is recommended if possible Frequency locki...

Страница 9: ...e EVM 1 With the FTDI SPI GUI open on the PC navigate to the Intro tab 2 Press the calibrate button to calibrate the ADC NOTE This calibrate button sets the ADC in power down mode and then returns the ADC to normal operation which executes core calibration Post power up calibration is only mandatory if the CLKDIV value is changed or if the sampling rate is changed 3 12 Verify the TSW14J56EVM Switc...

Страница 10: ...m the Test Options file menu to remove bins around DC eliminate DC noise and offset or the fundamental eliminate phase noise from signal generators Open the Capture Option dialog from the Data Capture Options file menu to change the capture depth or to enable FFT averaging For analyzing only a portion of the spectrum use the Single Tone test with the Bandwidth Integration Markers from the Test Opt...

Страница 11: ...he status of the D1 to D8 LEDs on the TSW14J56EVM See the Appendix A for more information regarding the status LEDs NOTE Note that D4 has changed to indicate that the JESD204B link is established Table 2 Default State of LEDs on the TSW14J56EVM during Typical Operation LED Status D1 Blinking D2 On D3 Blinking D4 Off D5 On D6 Off D7 Off D8 On FPGA_DONE On 11 SLAU529A February 2014 Revised December ...

Страница 12: ...LA and RAMP supported supported PRBS7 PRBS15 PRBS23 D21 5 K28 5 not supported at this D21 5 K28 5 ILA ramp patterns time supported Speed Lane rates from 7 4 down to 1 Lane rates from 7 4 Gb s Fs 370 MSPS down to 1 6 Gb s Gb s Fs 80 MSPS The Fs parameter must be properly set in HSDC Pro 4 2 Using the Device Configuration GUI The Device Configuration GUI must be installed separately from the HSDC Pr...

Страница 13: ...on Figure 4 Configuration GUI Intro Tab Figure 5 Configuration GUI ADC Core Tab 13 SLAU529A February 2014 Revised December 2014 ADC16DX370EVM User s Guide Submit Documentation Feedback Copyright 2014 Texas Instruments Incorporated ...

Страница 14: ...t read Write Register button Write to the register highlighted in the Register Map Summary with the value in the Write Data field Write All button Update all registers shown in the Register Map Summary with the values shown in the Register Map Summary Can be used to re synchronize the GUI with the state of the hardware Read Register button Read from the register highlighted in the Register Map Sum...

Страница 15: ... Device Configuration Figure 6 Low Level Register Control Tab 15 SLAU529A February 2014 Revised December 2014 ADC16DX370EVM User s Guide Submit Documentation Feedback Copyright 2014 Texas Instruments Incorporated ...

Страница 16: ... it is not lit press Reconnect FTDI button Try restarting the configuration GUI Configuration GUI is not Use the free FT_PROG software from FTDI chip and verify that the on board FTDI chip is able to connect to the EVM programmed with the product description ADC16DX370EVM Verify that the TSW14J56EVM is properly connected to the PC with a mini USB cable and that HSDP software is not the board seria...

Страница 17: ...itialization D3 Off Synchronization not request code group synchronization complete The status of this LED is only valid after attempting a data capture in HSDC Pro RX Device Clock D4 Blinking Device clock is being received from the LMK device on the EVM Not blinking Device clock not received D5 No Function DDR3 Memory Calibration Done D6 On Calibration not done Off Calibration done typical operat...

Страница 18: ...k both the ADC and receiving device to achieve deterministic latency A 4 Customizing the EVM for Optional Clocking Support By default the LMK04828 is configured as a clock distributer and divider and only provides clock signals to the receiving FPGA device The EVM is configured to require an ADC device clock from an external signal generator source through the CLK SMA connector These default confi...

Страница 19: ...esired providing an alternate reference clock for the LMK04828 may be required Possible options for providing the reference clock include Using an external signal generator to provide the reference via the EXTREF SMA connector If a separate signal generator is also used to provide the ADC device clock these two generators must be frequency locked together Placing a crystal oscillator module on Y1 ...

Страница 20: ...ring the warranty period to the address designated by TI and that are determined by TI not to conform to such warranty If TI elects to repair or replace such EVM TI shall have a reasonable time to repair such EVM or provide replacements Repaired EVMs shall be warranted for the remainder of the original warranty period Replaced EVMs shall be warranted for a new full ninety 90 day warranty period 3 ...

Страница 21: ...io transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this list having a gain greater than the maximum gain indicated for that type are strictly prohibited for use with this device Concernant les EVMs avec antennes d...

Страница 22: ... any load to the EVM output If there is uncertainty as to the load specification please contact a TI field representative During normal operation even with the inputs and outputs kept within the specified allowable ranges some circuit components may have elevated case temperatures These components include but are not limited to linear regulators switching transistors pass transistors current sense...

Страница 23: ...F REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF USE LOSS OF DATA OR BUSINESS INTERRUPTION NO CLAIM SUIT OR ACTION SHALL BE BROUGHT AGAINST TI MORE THAN ONE YEAR AFTER THE RELATED CAUSE OF ACTION HAS OCCURRED 8 2 Specific Limitations IN NO EVENT SHALL T...

Страница 24: ...esponsible for compliance with all legal regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related information or support that may be provided by TI Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failur...

Страница 25: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Texas Instruments ADC16DX370EVM ...

Отзывы: