background image

FCC Interference Statement for Class B EVM devices

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

3.2

Canada

3.2.1

For EVMs issued with an Industry Canada Certificate of Conformance to RSS-210 or RSS-247

Concerning EVMs Including Radio Transmitters:

This device complies with Industry Canada license-exempt RSSs. Operation is subject to the following two conditions:

(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.

Concernant les EVMs avec appareils radio:

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

Concerning EVMs Including Detachable Antennas:

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types
listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated.
Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited
for use with this device.

Concernant les EVMs avec antennes détachables

Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et
d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le
présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le
manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne
non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de
l'émetteur

3.3

Japan

3.3.1

Notice for EVMs delivered in Japan:

Please see

http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page

日本国内に

輸入される評価用キット、ボードについては、次のところをご覧ください。

http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page

3.3.2

Notice for Users of EVMs Considered “Radio Frequency Products” in Japan:

EVMs entering Japan may not be certified

by TI as conforming to Technical Regulations of Radio Law of Japan.

If User uses EVMs in Japan, not certified to Technical Regulations of Radio Law of Japan, User is required to follow the
instructions set forth by Radio Law of Japan, which includes, but is not limited to, the instructions below with respect to EVMs
(which for the avoidance of doubt are stated strictly for convenience and should be verified by User):

1.

Use EVMs in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal
Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for
Enforcement of Radio Law of Japan,

2.

Use EVMs only after User obtains the license of Test Radio Station as provided in Radio Law of Japan with respect to
EVMs, or

3.

Use of EVMs only after User obtains the Technical Regulations Conformity Certification as provided in Radio Law of Japan
with respect to EVMs. Also, do not transfer EVMs, unless User gives the same notice above to the transferee. Please note
that if User does not follow the instructions above, User will be subject to penalties of Radio Law of Japan.

Содержание ADC08060

Страница 1: ...tion 4 2 2 Hardware Setup Procedure 5 2 3 Software Setup Procedure 6 2 4 Quick Start Troubleshooting 8 3 Optimizing Evaluation Results 9 3 1 Clocking Optimization 9 3 2 Coherent Input Source 9 3 3 HSDC Pro Settings 9 4 Alternate Hardware Configurations 10 4 1 Clocking Options 10 4 2 Voltage Reference Options 10 Appendix A Jumper and Connector Descriptions 11 List of Figures 1 EVM Feature Locations...

Страница 2: ...the EVM evaluation kit ADC08060EVM Standard banana jack power supply cables The following list of equipment are items that are not included in the EVM evaluation kit but are items required for evaluation of this product in order to achieve the best performance TSW1400EVM Data Capture Board 5 V DC cable connector and mini USB cable Computer running Microsoft Windows 8 Windows 7 or Windows XP One lo...

Страница 3: ... 3 Evaluation Board Feature Identification Summary The EVM features are labeled in Figure 1 Figure 1 EVM Feature Locations 1 4 References ADC08060 data sheet SNAS167 available at www ti com product ADC08060 TSW1400EVM User s Guide SLWU079 available at www ti com tool TSW1400EVM High Speed Data Converter Pro software SLWC107 and User s Guide SLWU087 available at www ti com tool dataconverterpro sw ...

Страница 4: ...ist of the required software The References section of this document contains links to find the software on the TI website Important The software must be installed before connecting the ADC08060EVM and TSW1400EVM to the computer for the first time 2 1 1 High Speed Data Converter Pro GUI Installation The High Speed Data Converter Pro HSDC Pro is used to control the TSW1400EVM and analyze the captur...

Страница 5: ... Setup Procedure A typical test setup using the ADC08060EVM and TSW1400EVM is shown in Figure 2 This is the test setup used for the quick start procedure The rest of this section describes the hardware setup steps Figure 2 Quick Start Test Setup 2 2 1 TSW1400EVM Setup First set up the TSW1400EVM using the following steps 1 Connect the ADC08060EVM to the TSW1400EVM connecting pin 1 of the CMOS_INTE...

Страница 6: ...n be opened and configured once the hardware is properly set up 2 3 1 HSDC Pro GUI Configuration 1 Open High Speed Data Converter Pro by going to Start Menu All Programs Texas Instruments High Speed Data Converter Pro The GUI main page looks as shown in Figure 3 Figure 3 HSDC Pro GUI Main Panel 2 When prompted to select the capture board select the TSW1400 whose serial number corresponds to the se...

Страница 7: ...uation Module 9 The results from the captured data of Channel 1 should look like Figure 4 and the performance should be similar to Table 1 If this result is not achieved then see the Quick Start Troubleshooting section of this document Figure 4 Data Capture Results From Quick Start Procedure Table 1 Quick Start Performance Measurements Result Measured Value Units SNR 48 dBFS SFDR 68 dBFS ...

Страница 8: ...W1400EVM Verify that the EVM configuration GUI is communicating with the USB and that the configuration procedure has been followed Try capturing data in HSDC Pro to force an LED status update HSDC Pro software is not capturing good data or analysis results are incorrect Verify that the TSW1400EVM is properly connected to the PC with a mini USB cable and that the board serial number is properly id...

Страница 9: ... analog inputs must be frequency locked such as through 10 MHz references in order to achieve coherency 3 3 HSDC Pro Settings HSDC Pro has some settings that can help improve the performance measurements These are highlighted in Table 3 Table 3 HSDC Pro Settings to Optimize Results HSDC Pro Feature Description Analysis Window Samples Selects the number of samples to include in the selected test an...

Страница 10: ...Hz signal from an RF generator to the SMA connection on the EVM J3 4 2 Voltage Reference Options The default configurations uses a LM8272 rail to rail precision op amp to drive the reference voltage By default the top reference voltage is set to 1 9 V and the bottom voltage is set to 0 3 V Alternative options are described in the follow sections 4 2 1 External Voltage Reference An external voltage...

Страница 11: ...o bypass clock buffer bypassed by default Shunt pins 1 2 JP4 Enable outputs from clock buffer active high Shunt pins 1 2 JP5 Option to bypass clock buffer bypassed by default Shunt pins 1 2 JP6 Powerdown mode for ADC08060 default not in powerdown mode Shunt pins 2 3 JP7 Provides power to onboard clock powered by default Shunt pins 1 2 JP8 Top reference voltage option supplied by LM8272 by default ...

Страница 12: ...y set forth above or credit User s account for such EVM TI s liability under this warranty shall be limited to EVMs that are returned during the warranty period to the address designated by TI and that are determined by TI not to conform to such warranty If TI elects to repair or replace such EVM TI shall have a reasonable time to repair such EVM or provide replacements Repaired EVMs shall be warr...

Страница 13: ...the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this list having a gain greater than the maximum gain indicated for that type are strictly prohibited for use with this device Concernant les EVMs avec antennes détachables Conformément à la réglementation d Industrie Canada le présent émetteur radio peut fo...

Страница 14: ...ed loads Any loads applied outside of the specified output range may also result in unintended and or inaccurate operation and or possible permanent damage to the EVM and or interface electronics Please consult the EVM user guide prior to connecting any load to the EVM output If there is uncertainty as to the load specification please contact a TI field representative During normal operation even ...

Страница 15: ...COST OF REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF USE LOSS OF DATA OR BUSINESS INTERRUPTION NO CLAIM SUIT OR ACTION SHALL BE BROUGHT AGAINST TI MORE THAN TWELVE 12 MONTHS AFTER THE EVENT THAT GAVE RISE TO THE CAUSE OF ACTION HAS OCCURRED 8 2 Specif...

Страница 16: ... TI Resource NO OTHER LICENSE EXPRESS OR IMPLIED BY ESTOPPEL OR OTHERWISE TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT OF TI OR ANY THIRD PARTY IS GRANTED HEREIN including but not limited to any patent right copyright mask work right or other intellectual property right relating to any combination machine or process in which TI product...

Отзывы: