Texas Electronics TD-104-5D Скачать руководство пользователя страница 3

FEATURES & BENEFITS

•  Superior low starting threshold

•  Long life hybrid single wiper potentiometer

•  No plastic parts for extremely long life

•  Precision stainless steel bearings for stability and repeatability

•  Crossarm included with purchase of matching wind speed sensor

•  Easy installation and maintenance

•  Over 25 years in production

•  Lightweight and rugged anodized aluminum exterior

INSTALLATION & MAINTENANCE

Installation consists of attaching the unit to a mast via the supplied mounting pole. If a crossarm is used, 

the entire unit can be bolted to a mast or attached via U-bolts. 

The sensor is dynamically calibrated at the factory and due to the nature of its operation should not require 

field calibration. Calibration is a matter of proper orientation during installation. A magnetic compass is 

recommended for proper orientation. Field maintenance should include occasional cleaning of the vane 

assembly and inspection of the internal mechanism to make sure it is free from insects and debris. In some 

applications users may need to occasionally verify and document sensor accuracy with a calibration dial/

vane. Possible bearing and potentiometer replacement every three to five years is recommended to main-

tain low starting threshold. 

ORDERING INFORMATION

Model #   

 

Description

TD-104-5D   

Wind Direction Sensor, Heavy Industrial

TD-104-5D-A  

Wind Direction Sensor, 4-20 mA

* Sensor is designed to work with TV-114 wind speed sensor.

Optional Parts / Accessories

Содержание TD-104-5D

Страница 1: ...Fax 214 631 4218 www texaselectronics com Texas Electronics Inc Tel 214 631 2490 Dallas TX 75235 5529 Redfield Street TD 104 5D TD 104 5D A Wind Direction Sensor User s Manual ...

Страница 2: ...al Presentation 10000 ohm potentiometer 4 20 mA 0 357 electrical 0 355 electrical 3 VDC excitation minimum 10 30 VDC Performance Accuracy 3 0 3 0 Potentiometer linearity 0 5 0 5 Starting Threshold 2 5 mph 1 1 m s 2 5 mph 1 1 m s Damping Ratio 30 36 30 36 Damped Wavelength 19 7 6 0 m 19 7 6 0 m Delay Distance 4 8 1 15 m 4 8 1 15 m Resolution 1 1 Environmental Operational Envelope 0 135 mph 0 to 60 ...

Страница 3: ...tory and due to the nature of its operation should not require field calibration Calibration is a matter of proper orientation during installation A magnetic compass is recommended for proper orientation Field maintenance should include occasional cleaning of the vane assembly and inspection of the internal mechanism to make sure it is free from insects and debris In some applications users may ne...

Страница 4: ...ion site Turbulence and other local effects can be reduced somewhat by mounting sensors on the upwind end of the building the end of the building exposed to the most common local prevailing winds Horizon tal mount booms that extend from existing towers should be fabricated so that sensors will extend a distance of 5 to 10 feet from the tower assembly dependent on tower thickness Wind direction sen...

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ...tain defective material or workman ship and will return said equipment to purchaser F O B TEI Texas Electronics shall not be obligated how ever to repair or replace equipment which has been repaired by others abused improperly installed altered or otherwise misused or damaged in any way TEI will not be responsible for any dismantling re assembly or reinstallation charges This warranty is in lieu o...