15
Chapter 6: Setting Top Platen Temperature
To set the temperature of the top platen, perform the following:
While the control panel is in Monitoring Mode, press and hold the Top Temp button.
After approximately two seconds, the panel’s Up Arrow and Down Arrow buttons will
light and the Top Temp button blinks, as show in Figure 6-1. This puts the control
panel in the Set Mode. Release the Top Temp button. The control panel displays the
current setting for the top platen temperature (not the actual temperature, as shown
in Monitoring Mode); if the platen is set to off, the control panel displays three
dashes.
Figure 6-1
Setting Top Platen Temperature
Press either the Up Arrow or the Down Arrow button to change the setting; press and
release to increase or decrease the setting by one (1). To rapidly change the value,
press and hold the appropriate arrow button. Possible top platen temperature values
range from 100° to 450° Fahrenheit. To turn off the top platen, set the value as three
dashes,
one above 450° and one below 100°.
After you reach the temperature that you want to set for the top platen, press and
release the Top Temp button again to save the setting and return the control panel to
Monitoring Mode.
Содержание DES-32
Страница 1: ...Heat Seal Machine DES 32 Texas Automation Products Inc 300 Nichols Drive Hutchins TX 75141 ...
Страница 22: ......
Страница 23: ......