5 Clock
All three differential clock inputs are directly routed to the SiCA Connector.
A Harting connector 27 21 121 8000 or compatible is used for the Clock inputs.
The Clock Inputs are directly routed to the TAMC900.
The maximum input voltage of the corresponding Virtex-5 I/Os is 2.5
Volt.